MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jocmr.2025.101981

Медицинская библиотека · Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025

Exercise cardiovascular magnetic resonance myocardial dynamic index: A non-invasive imaging marker associated with cardiac dyspnea.

Ghanbari Fahime, Rodriguez Jennifer, Morales Manuel A, Ngo Long H, Tsao Connie W, Robbins Jeremy M, Gopal Deepa M, Systrom David M, Waxman Aaron B, Manning Warren J, Nezafat Reza

СтатьяМногоцентровое исследованиеПоддержка NIH: внешняя программаПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

BACKGROUND

Identifying the cause of dyspnea (i.e., cardiac vs. non-cardiac) can be challenging in the absence of significant resting cardiac abnormalities. Exercise cardiovascular magnetic resonance (Ex-CMR) enables quantification of cardiac volumetric indices under physiological stress. Using Ex-CMR, we sought to develop a non-invasive imaging marker, referred to as the myocardial dynamic index (MDI), and to demonstrate its potential for evaluating cardiac dyspnea.

METHODS

MDI is a metric derived from Ex-CMR work-volume loop model that integrates rest and stress left ventricular (LV) end-diastolic and end-systolic volumes with workload measured during supine exercise, while accounting for body size and LV mass. To evaluate MDI as a marker of cardiac dyspnea, we retrospectively analyzed data from a prospective multicenter study measuring MDI in patients with cardiac or non-cardiac dyspnea. All had invasive exercise testing before Ex-CMR. Cardiac dyspnea was defined by established invasive and non-invasive criteria, including HFpEF (early to advanced) and HFmrEF. Non-cardiac dyspnea patients had normal invasive hemodynamics and cardiac function. Univariable and multivariable logistic regression identified clinical and imaging predictors of cardiac dyspnea. A base model incorporating clinical and rest CMR variables was compared to a model that included the base model plus MDI. Diagnostic performance was assessed using receiver operating characteristic analysis and compared using the DeLong test. MDI scan/re-scan reproducibility over one year, inter- and intra-observer reproducibility, and correlation with VO₂ max were evaluated.

RESULTS

Among 93 patients (66 with cardiac dyspnea, 27 with non-cardiac dyspnea), MDI was lower in patients with cardiac dyspnea (25.9±9.5 vs. 45.1±10.7 mL·W/g/m², p<0.0001). The base model included age, body mass index, NYHA class, and left atrial strain. In multivariable analysis, MDI emerged as the only independent predictor of cardiac dyspnea when added to the base model. Inclusion of MDI improved the AUC from 0.86 to 0.93 (p=0.012), while MDI alone yielded an AUC of 0.91. A strong correlation was observed between MDI and the VO₂ max index (r=0.84, p<0.0001). Reproducibility was excellent.

CONCLUSION

Ex-CMR MDI is independently associated with cardiac dyspnea and strongly correlates with the VO₂ max index. It aids in differentiating cardiac from non-cardiac dyspnea and provides incremental diagnostic value beyond conventional clinical and resting imaging parameters.

Для цитирования: Ghanbari Fahime, Rodriguez Jennifer, Morales Manuel A, Ngo Long H, Tsao Connie W, Robbins Jeremy M, Gopal Deepa M, Systrom David M, Waxman Aaron B, Manning Warren J, Nezafat Reza. Exercise cardiovascular magnetic resonance myocardial dynamic index: A non-invasive imaging marker associated with cardiac dyspnea.. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2025. DOI: 10.1016/j.jocmr.2025.101981.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.