MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.oa.18.00001

Медицинская библиотека · JB & JS open access · 2018

A Clinical Test to Measure Airborne Microbial Contamination on the Sterile Field During Total Joint Replacement: Method, Reference Values, and Pilot Study.

Harp John H

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Airborne microbe-carrying particles in the operating-room environment during total joint replacement are a risk factor for periprosthetic joint infection. The present study focuses on a simple environmental test, based on practices used in aseptic cleanrooms, to quantify the deposition of microbe-carrying particles onto the sterile field.

METHODS

Settle plates are exposed Petri dishes. A settle plate test system and sampling plan were developed from current practices used in aseptic manufacturing. A pilot study evaluated this system in an orthopaedic operating room during 22 total knee and hip arthroplasties. The microbial deposition total (MDT), expressed in colonies/m2, is proposed as an outcome variable to report airborne sterile-field contamination as measured with settle plates. Two reference MDT levels were developed: (1) an upper limit of 450, corresponding with the ultraclean air definition of 10 colonies/m3, and (2) a target level of 100, corresponding with 1 colony/m3. These levels also correspond with widely used limits in aseptic cleanrooms and controlled environments.

RESULTS

High MDT standard deviations were noted. Ninety-one percent (95% confidence interval, 71.0% to 98.7%) of wound zone MDT levels were within the upper limit. Twenty-seven percent (95% confidence interval, 12.9% to 48.4%) of wound zone levels were within the target level.

CONCLUSIONS

Settle plates are a feasible technique to test environmental levels of microbe-carrying particles on sterile fields during total joint replacement for scientific and environmental quality studies.

CLINICAL RELEVANCE: This settle plate operating-room environmental test can be used in future research to validate the presence of actual ultraclean-air conditions during periprosthetic joint infection outcome studies. Surgeons also can use this test to measure intraoperative airborne microbe-carrying-particle sterile-field contamination and compare it with ultraclean-air reference levels for environmental quality-control programs.

Для цитирования: Harp John H. A Clinical Test to Measure Airborne Microbial Contamination on the Sterile Field During Total Joint Replacement: Method, Reference Values, and Pilot Study.. JB & JS open access. 2018. DOI: 10.2106/jbjs.oa.18.00001.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.