MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/00912700022009134

Медицинская библиотека · Journal of clinical pharmacology · 2000

A study comparing the clinical pharmacokinetics, pharmacodynamics, and tolerability of triamcinolone acetonide HFA-134a metered-dose inhaler and budesonide dry-powder inhaler following inhalation administration.

Argenti D, Shah B, Heald D

Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

The impending phaseout of chlorofluorocarbons as propellants in pressurized metered-dose inhalers used in the treatment of asthma has resulted in the development of alternative devices to deliver drug to the pulmonary airways. These alternative devices include metered-dose inhalers using environmentally friendly hydroflurocarbon propellants and breath-actuated dry-powder inhalers. The purpose of this study was to compare the single- and multiple-dose pharmacokinetics, pharmacodynamics, and tolerability of a newly developed hydroflurocarbon formulation of triamcinolone acetonide (Azmacort HFA 225 mcg Inhalation Aerosol) to that of the dry-powder formulation of budesonide (Pulmicort Turbuhaler 200 mcg). This three-way crossover study used 18 normal healthy subjects each receiving a 675 mcg dose of triamcinolone acetonide, 600 mcg dose of budesonide, or placebo twice a day for 5 days. Serial plasma samples were collected after the first and last dose of test medication for pharmacokinetic analysis. Pharmacodynamics were assessed by changes in hypothalamic-pituitary-adrenal axis function as measured by 8 a.m. serum cortisol, 24-hour overnight serum cortisol AUC(0-24), and 24-hour urinary-free cortisol after the last evening dose of test drug. Tolerability was assessed through physical examinations, vital signs, 12-lead ECG, routine clinical labs, and adverse events recording. Both compounds were systemically absorbed. However, no significant drug accumulation was noted with chronic dosing. Chronic dosing did result in a statistically significant 20% reduction in basal 24-hour serum cortisol AUC(0-24) for both compounds. There were no clinically significant abnormalities in physical examination, vital signs, 12-lead ECG, or routine clinical labs noted during the study. Overall, the study drugs were well tolerated, with adverse events characterized as mild to moderate in severity.

Для цитирования: Argenti D, Shah B, Heald D. A study comparing the clinical pharmacokinetics, pharmacodynamics, and tolerability of triamcinolone acetonide HFA-134a metered-dose inhaler and budesonide dry-powder inhaler following inhalation administration.. Journal of clinical pharmacology. 2000. DOI: 10.1177/00912700022009134.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.