MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/sla.0000000000001533

Медицинская библиотека · Annals of surgery · 2016

Conventional Mechanical Ventilation Versus High-frequency Oscillatory Ventilation for Congenital Diaphragmatic Hernia: A Randomized Clinical Trial (The VICI-trial).

Snoek Kitty G, Capolupo Irma, van Rosmalen Joost, Hout Lieke de Jongste-van den, Vijfhuize Sanne, Greenough Anne, Wijnen René M, Tibboel Dick, Reiss Irwin K M, CDH EURO Consortium

Сравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To determine the optimal initial ventilation mode in congenital diaphragmatic hernia.

BACKGROUND

Congenital diaphragmatic hernia is a life-threatening anomaly with significant mortality and morbidity. The maldeveloped lungs have a high susceptibility for oxygen and ventilation damage resulting in a high incidence of bronchopulmonary dysplasia (BPD) and chronic respiratory morbidity.

METHODS

An international, multicenter study (NTR 1310), the VICI-trial was performed in prenatally diagnosed congenital diaphragmatic hernia infants (n = 171) born between November 2008 and December 2013, who were randomized for initial ventilation strategy.

RESULTS

Ninety-one (53.2%) patients initially received conventional mechanical ventilation and 80 (46.8%) high-frequency oscillation. Forty-one patients (45.1%) randomized to conventional mechanical ventilation died/ had BPD compared with 43 patients (53.8%) in the high-frequency oscillation group. An odds ratio of 0.62 [95% confidence interval (95% CI) 0.25-1.55] (P = 0.31) for death/BPD for conventional mechanical ventilation vs high-frequency oscillation was demonstrated, after adjustment for center, head-lung ratio, side of the defect, and liver position. Patients initially ventilated by conventional mechanical ventilation were ventilated for fewer days (P = 0.03), less often needed extracorporeal membrane oxygenation support (P = 0.007), inhaled nitric oxide (P = 0.045), sildenafil (P = 0.004), had a shorter duration of vasoactive drugs (P = 0.02), and less often failed treatment (P = 0.01) as compared with infants initially ventilated by high-frequency oscillation.

CONCLUSIONS

Our results show no statistically significant difference in the combined outcome of mortality or BPD between the 2 ventilation groups in prenatally diagnosed congenital diaphragmatic hernia infants. Other outcomes, including shorter ventilation time and lesser need of extracorporeal membrane oxygenation, favored conventional ventilation.

Для цитирования: Snoek Kitty G, Capolupo Irma, van Rosmalen Joost, Hout Lieke de Jongste-van den, Vijfhuize Sanne, Greenough Anne, Wijnen René M, Tibboel Dick, Reiss Irwin K M, CDH EURO Consortium. Conventional Mechanical Ventilation Versus High-frequency Oscillatory Ventilation for Congenital Diaphragmatic Hernia: A Randomized Clinical Trial (The VICI-trial).. Annals of surgery. 2016. DOI: 10.1097/sla.0000000000001533.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.