MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.athoracsur.2013.11.036

Медицинская библиотека · The Annals of thoracic surgery · 2014

Long-term durability of bicuspid aortic valve repair.

Svensson Lars G, Al Kindi Adil H, Vivacqua Alessandro, Pettersson Gösta B, Gillinov A Marc, Mihaljevic Tomislav, Roselli Eric E, Sabik Joseph F, Griffin Brian, Hammer Donald F, Rodriguez Leonardo, Williams Sarah J, Blackstone Eugene H, Lytle Bruce W

Сравнительное исследованиеОценочное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Bicuspid aortic valve (BAV) is the most common congenital cardiac malformation, occurring in 1% to 2% of the population. Eventually, 20% develop clinically important valvar regurgitation requiring surgical intervention. Aortic valve repair avoids anticoagulation and prosthetic valve-related complications. This study evaluated long-term durability of BAV repair.

METHODS

From 1985 to 2011, 728 patients, mean age 42±12 years, underwent BAV repair at Cleveland Clinic. Mean follow-up was 9.0±6.2 years (median, 8.3). Factors associated with repair durability (expressed as aortic valve reoperations and echocardiographically estimated gradients and regurgitation) and survival were identified.

RESULTS

Hospital mortality was 0.41% (n=3), and stroke occurred in 0.27% (n=2). Freedom from aortic valve reoperation at 10 years was 78%. Risk of reoperation was highest immediately after operation and fell rapidly to approximately 2.6%/year up to 15 years. Primary reasons for reoperation were cusp prolapse (38%), aortic stenosis or regurgitation (17%), and aortic regurgitation from root aneurysm (15%). Aortic valve gradients showed an early initial peak, rapidly declined, then rose steadily, accompanied by an increase in left ventricular mass. Survival was 94% at 10 years. A risk factor for early death was greater preoperative mitral valve regurgitation, and for late death, older age at operation, more severe symptoms, and poorer left ventricular function.

CONCLUSIONS

BAV repair is safe and durable with low mortality, low prevalence of reoperation, and good long-term survival. Cusp prolapse from technical errors and natural progression of disease are the most common causes for reoperation, but progressive natural increase in valve gradient accounts for a substantial proportion as well.

Для цитирования: Svensson Lars G, Al Kindi Adil H, Vivacqua Alessandro, Pettersson Gösta B, Gillinov A Marc, Mihaljevic Tomislav, Roselli Eric E, Sabik Joseph F, Griffin Brian, Hammer Donald F, Rodriguez Leonardo, Williams Sarah J, Blackstone Eugene H, Lytle Bruce W. Long-term durability of bicuspid aortic valve repair.. The Annals of thoracic surgery. 2014. DOI: 10.1016/j.athoracsur.2013.11.036.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.