MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1101/2025.10.24.684439

Медицинская библиотека · bioRxiv : the preprint server for biology · 2025

Distinct Roles of Surface Nanostructure and Polymer Degradation in Fibroblast Response to Device Design.

Pawelec Kendell M, Shapiro Erik M

СтатьяПрепринтПеревод в очереди

Аннотация

Fibrotic encapsulation of implanted biomedical devices represents the highest cause of device failure across numerous fields, including orthopedics, breast implants and neural electrodes. While most research has focused on the immune system for driving the foreign body response to devices, fibroblasts are emerging as another key regulator of tissue response. In the present study, we evaluated the effects of porous device design on the activation of primary human dermal fibroblasts into myofibroblasts, a contractile cell that is a hallmark of fibrosis, over four weeks in culture. In particular two factors were studied 1) the introduction of nanoparticles, as they are increasingly being used for device functionalization, and 2) the polymer matrix, which dictates chemistry, mechanics and degradation. The addition of tantalum oxide (TaOx) nanoparticles (0-20wt%) had a minimal effect on fibroblasts, significantly down-regulating expression of alpha smooth muscle actin (αSMA) (0.31 ± 0.1), likely driven by the increase in nanoscale surface roughness. The polymer matrix of the device caused significant changes to myofibroblast activation, with the fast degrading polymer, poly(lactide co-glycolide) (PLGA) 50:50, significantly up-regulating multiple myofibroblast markers, including αSMA (5.16 ± 2.5), vinculin, integrin β1, and integrin β5, compared to non-degrading polycaprolactone (PCL). The effect was due to the release of degradation products, namely lactic acid, which affects cellular metabolism. Together this highlights that device design affects biological response immediately post-implantation in ways that impact the ultimate success or failure of biomedical devices.

Для цитирования: Pawelec Kendell M, Shapiro Erik M. Distinct Roles of Surface Nanostructure and Polymer Degradation in Fibroblast Response to Device Design.. bioRxiv : the preprint server for biology. 2025. DOI: 10.1101/2025.10.24.684439.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.