MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1471-0528.2005.00486.x

Медицинская библиотека · BJOG : an international journal of obstetrics and gynaecology · 2005

Prediction of congenital toxoplasmosis by polymerase chain reaction analysis of amniotic fluid.

Thalib L, Gras L, Romand S, Prusa A, Bessieres M-H, Petersen E, Gilbert R E

Оценочное исследованиеСтатьяМногоцентровое исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To determine the accuracy of polymerase chain reaction (PCR) analysis of amniotic fluid for fetal toxoplasmosis according to clinical predictors of outcome and study centre.

DESIGN

Prospective cohort study.

SETTING

Nine European centres.

POPULATION: Women with suspected toxoplasma infection identified by prenatal screening.

METHODS

Logistic regression was used to examine the effects of gestational age at maternal seroconversion, treatment and timing of amniocentesis, on PCR accuracy, and to calculate the post-test probability of congenital toxoplasmosis.

MAIN OUTCOME MEASURES: Infants had congenital toxoplasmosis if specific IgG persisted beyond 11.5 months. Uninfected infants had undetectable IgG in the absence of anti-toxoplasma treatment.

RESULTS

Of 593 PCR results, 64 were positive (57 confirmed infected), and 529 were negative (23 confirmed infected). The likelihood ratio for a positive PCR result decreased significantly with trimester at seroconversion, but did not change significantly for a negative result. Weak associations were detected between sensitivity and, inversely, with specificity, and gestational age at maternal seroconversion. There was no significant association between sensitivity and centre, type or duration of treatment, or timing of amniocentesis. Specificity differed significantly between centres (P < 0.001). The change in pre- to post-test probability of infection was maximal for a positive PCR after first trimester seroconversion, affecting 1% of women tested, and a negative PCR after third trimester seroconversion, affecting half the women tested.

CONCLUSIONS

Prediction of the risk of congenital toxoplasmosis should combine estimates of test accuracy and maternal-fetal transmission, which take account of the gestational age at which the mother seroconverted. Local laboratory standards will affect the generalisability of these results.

Для цитирования: Thalib L, Gras L, Romand S, Prusa A, Bessieres M-H, Petersen E, Gilbert R E. Prediction of congenital toxoplasmosis by polymerase chain reaction analysis of amniotic fluid.. BJOG : an international journal of obstetrics and gynaecology. 2005. DOI: 10.1111/j.1471-0528.2005.00486.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.