Value of routine echocardiography in the management of stroke.
Аннотация
BACKGROUND
Transthoracic echocardiography is routinely performed in patients with stroke or transient ischemic attack (TIA) to help plan secondary stroke management, but recent data evaluating its usefulness in this context are lacking. We sought to evaluate the value of echocardiography for identifying clinically actionable findings for secondary stroke prevention.
METHODS
We conducted a multicentre cohort study of patients admitted to hospital with stroke or TIA between 2010 and 2015 at 2 academic hospitals in Toronto, Ontario, Canada. Clinically actionable echocardiographic findings for secondary stroke prevention included cardiac thrombus, patent foramen ovale, atrial myxoma or valvular vegetation. We identified patient characteristics associated with clinically actionable findings using logistic regression.
RESULTS
Of the 1862 patients with stroke or TIA we identified, 1272 (68%) had at least 1 echocardiogram. Nearly all echocardiograms were transthoracic; 1097 (86%) were normal, 1 (0.08%) had an atrial myxoma, 2 (0.2%) had a valvular vegetation, 11 (0.9%) had a cardiac thrombus and 66 (5.2%) had a PFO. Patent foramen ovale was less likely among patients older than 60 years (adjusted odds ratio [OR] 0.34, 95% confidence interval [CI] 0.20-0.57), with prior stroke or TIA (adjusted OR 0.31, 95% CI 0.09-0.76) or with dyslipidemia (adjusted OR 0.39, 95% CI 0.15-0.84). Among the 130 patients with cryptogenic stroke who had an echocardiogram (n = 110), a PFO was detected in 19 (17%) on transthoracic echocardiogram.
INTERPRETATION: Most patients with stroke or TIA had a normal echocardiogram, with few having clinically actionable findings for secondary stroke prevention. Clinically actionable findings, specifically PFO, were more common in patients with cryptogenic stroke.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.