MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7507/1002-1892.20160245

Медицинская библиотека · Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2016

[EFFECTIVENESS OF PROXIMAL HUMERAL INTERNAL LOCKING SYSTEM PLATE FOR PROXIMAL HUMERUS FRACTURES].

Qin Bengang, Li Ping, Yang Jiantao, Yang Yi, Fu Guo, Wang Honggang, Qi Jian, Zhu Qingtang, Gu Liqiang

Аннотация на английскомСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To analyze the effectiveness of proximal humeral internal locking system (Philos) plate for proximal humerus fracture.

METHODS

Thirty-three patients with proximal humerus fracture were treated with open reduction and internal fixation with Philos plate between January 2009 and January 2014. There were 19 males and 14 females, aged 23-89 years (mean, 56.6 years). The left side was involved in 15 cases, and the right side in 18 cases. The injury causes included falling in 20 cases and traffic accident in 13 cases. All cases received X-ray and CT scan and three-dimensional reconstruction before operation. According to the Neer classification, 8 cases were rated as two-part fractures, 15 cases as three-part fractures, and 10 cases as four-part fractures. The interval time between injury and surgery was 1-7 days (mean, 3.67 days). Postoperative functional outcome was evaluated using the Constant-Murley score.

RESULTS

Infection and liquefaction occurred in 2 cases respectively, which was cured after corresponding treatment; primary healing of wound was obtained in the other 29 cases. Five patients had shoulder pain. The patients were followed up 11-47 months (mean, 33 months). The mean time of fracture union was 7.5 months (range, 5-9 months) on the X-ray films. Humeral head necrosis occurred in 2 patients with Neer four-part fractures, and internal fixation failure occurred in 3 patients (2 screw broken and 1 plate broken) with four-part fractures (2 cases) and three-part fractures (1 case), which was cured after conservative treatment. At last follow-up, the mean Constant-Murley score was 70.5 (range, 42-90); the results were excellent in 3 cases, good in 21 cases, moderate in 6 cases, and poor in 3 cases.

CONCLUSIONS

Satisfactory results can be expected for proximal humeral fracture by using of the proximal humeral internal locking system plate based on strict indication and early rehabilitation training.

Для цитирования: Qin Bengang, Li Ping, Yang Jiantao, Yang Yi, Fu Guo, Wang Honggang, Qi Jian, Zhu Qingtang, Gu Liqiang. [EFFECTIVENESS OF PROXIMAL HUMERAL INTERNAL LOCKING SYSTEM PLATE FOR PROXIMAL HUMERUS FRACTURES].. Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery. 2016. DOI: 10.7507/1002-1892.20160245.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.