MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12866-024-03189-5

Медицинская библиотека · BMC microbiology · 2024

Development of a multiple cross displacement amplification combined with nanoparticles-based biosensor assay for rapid and sensitive detection of Streptococcus pyogenes.

Dou Zhiqian, Xie Ling, Gao Meiling, Liu Dexi

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

S. pyogenes, is a primary pathogen that leads to pharyngitis and can also trigger severe conditions like necrotizing fasciitis and streptococcal toxic shock syndrome (STSS), often resulting in high mortality rates. Therefore, prompt identification and appropriate treatment of S. pyogenes infections are crucial in preventing the worsening of symptoms and alleviating the disease's impact.

RESULTS

In this study, a newly developed technique called multiple cross displacement amplification (MCDA) was employed to detect S. pyogenes,specifically targeting the speB gene, at a temperature of 63°C within 30 min. Then, an easily portable and user-friendly nanoparticles-based lateral flow biosensor (LFB) assay was introduced for the rapid analysis of MCDA products in just 2 min. The results indicated that the LFB offers greater objectivity compared to Malachite Green and is simpler than electrophoresis. The MCDA-LFB assay boasts a low detection limit of 200 fg and exhibits no cross-reaction with non-S. pyogenes strains. Among 230 clinical swab throat samples, the MCDA-LFB method identified 27 specimens as positive, demonstrating higher sensitivity compared to 23 samples detected positive by qPCR assay and 18 samples by culture. The only equipment needed for this assay is a portable dry block heater. Moreover, each MCDA-LFB test is cost-effective, priced at approximately $US 5.5.

CONCLUSION

The MCDA-LFB assay emerges as a straightforward, specific, sensitive, portable, and user-friendly method for the rapid diagnosis of S. pyogenes in clinical samples.

Для цитирования: Dou Zhiqian, Xie Ling, Gao Meiling, Liu Dexi. Development of a multiple cross displacement amplification combined with nanoparticles-based biosensor assay for rapid and sensitive detection of Streptococcus pyogenes.. BMC microbiology. 2024. DOI: 10.1186/s12866-024-03189-5.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.