MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jpedsurg.2019.04.026

Медицинская библиотека · Journal of pediatric surgery · 2019

Outcomes of multi-gestational pregnancies affected by esophageal atresia - tracheoesophageal fistula.

Forster Corey, Zamiara Paul, Lapidus-Krol Eveline, Chiang Monping, Scaini Vikki, Haliburton Beth, Moore Aideen M, Marcon Margaret A, Chiu Priscilla P L

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Contemporary outcomes of infants with esophageal atresia with or without tracheoesophageal fistula (EA/TEF) from multi-gestational pregnancies compared to those of singleton pregnancies have not been reported.

METHODS

A single-center retrospective review of EA/TEF patients born from 1999 to 2013 was performed. Patient demographics, gestational age (GA), birth weight, associated anomalies, requirement for gastrostomy tube and mortality were reviewed.

RESULTS

Singleton EA/TEF patients outnumbered those from multi-gestational pregnancies nearly 10:1 (214 vs 22 patients). EA/TEF patients from multi-gestational pregnancies were more likely to be premature (77% vs. 32%), have lower birth weight (mean 1766 g vs. 2695 g), have associated duodenal atresia (18% vs. 6%) and require gastrostomy tube (41% vs. 33%) for feeding challenges compared to EA/TEF singletons. Mortality was also significantly greater for multi-gestational EA/TEF patients compared to singleton EA/TEF patients (18% vs. 6%).

CONCLUSION

EA/TEF infants from multi-gestational pregnancies have greater clinical complexity and mortality than singleton EA/TEF patients. Parents of EA/TEF multi-gestational infants should be appropriately counseled and supported.

Для цитирования: Forster Corey, Zamiara Paul, Lapidus-Krol Eveline, Chiang Monping, Scaini Vikki, Haliburton Beth, Moore Aideen M, Marcon Margaret A, Chiu Priscilla P L. Outcomes of multi-gestational pregnancies affected by esophageal atresia - tracheoesophageal fistula.. Journal of pediatric surgery. 2019. DOI: 10.1016/j.jpedsurg.2019.04.026.