MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.49550

Медицинская библиотека · Cureus · 2023

Minimally Invasive Approach for Diffuse Idiopathic Skeletal Hyperostosis (DISH)-Related Vertebral Fractures: A Case Report on Combining Vertebral Cement Augmentation and Cement-Augmented Pedicle Screw Instrumentation.

Inoue Takaki, Motegi Hiroyuki

Клинический случайСтатьяПеревод в очереди

Аннотация

Diffuse idiopathic skeletal hyperostosis (DISH)-related vertebral fractures often require surgical intervention due to associated spinal instability and neurological deficits. This study presents a minimally invasive approach that utilizes vertebral cement augmentation and cement-augmented pedicle screw (PS) instrumentation to manage DISH-related vertebral fractures. We present an 87-year-old male patient with a T11 vertebral fracture associated with DISH. Despite the patient's advanced age and comorbidities, he underwent a successful surgical procedure, achieving relatively short-segment fixation by combining vertebral cement augmentation and cement-augmented PS instrumentation. After the surgery, the patient's lower back pain subsided, facilitating a return to normal activities. Radiographic evaluation at the six-month postoperative stage confirmed the maintenance of vertebral body reduction with no indications of implant failure. In DISH-associated vertebral fractures, the combined application of vertebral cement augmentation and cement-augmented PS instrumentation offers a minimally invasive solution that expedites fracture stabilization and enhances patient outcomes. This approach offers the potential for effective fracture stabilization and a significant reduction in postoperative complications, holding promise for managing challenging cases in this patient population.

Для цитирования: Inoue Takaki, Motegi Hiroyuki. Minimally Invasive Approach for Diffuse Idiopathic Skeletal Hyperostosis (DISH)-Related Vertebral Fractures: A Case Report on Combining Vertebral Cement Augmentation and Cement-Augmented Pedicle Screw Instrumentation.. Cureus. 2023. DOI: 10.7759/cureus.49550.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.