MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5664/jcsm.11272

Медицинская библиотека · Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2024

Gefapixant as a P2X3 receptor antagonist treatment for obstructive sleep apnea: a randomized controlled trial.

Robbins Jonathan A, Sands Scott, Maganti Lata, Crumley Tami, Fox-Bosetti Sabrina, Hussain Azher, Schwartz Howard, Safirstein Beth, Ahmad Maha, Dragone Leonard, Nussbaum Jesse, Kushida Clete, Iwamoto Marian, Stoch S Aubrey

СтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

STUDY

OBJECTIVES

Obstructive sleep apnea (OSA) is a highly prevalent disorder with serious health consequences but limited therapeutic options. For a subset of those with OSA, a key underlying mechanism is hypersensitive chemoreflex control of breathing. There is no approved therapy that targets this endotypic trait. Here we determine whether the P2X3 receptor antagonist gefapixant, which is predicted to attenuate hypersensitive carotid chemoreflexes, reduces OSA severity in patients with chemoreflex-dependent OSA.

METHODS

In a randomized placebo-controlled crossover study, 24 patients with moderate-to-severe OSA (aged 39-68 years, non-continuous positive airway pressure users) whose disorder was partially responsive to supplemental oxygen (chemoreflex-dependent OSA) were treated with gefapixant 180 mg (or placebo) administered as tablets taken orally before bedtime for 7 days and assessed via overnight polysomnography. The primary analysis examined whether gefapixant treatment resulted in a greater reduction in the apnea-hypopnea index from baseline than placebo.

RESULTS

Gefapixant did not lower the apnea-hypopnea index significantly more than placebo; the estimated ratio of the apnea-hypopnea index on gefapixant vs placebo was 0.92 (90% confidence interval: 0.73, 1.17). Notably, nocturnal hypoxemia was increased (ratio of total sleep time with saturated peripheral oxygen < 90% on gefapixant vs placebo = 2.08 [90% confidence interval: 1.53, 2.82]), consistent with reduced chemoreflex output. Commonly reported adverse events with gefapixant included ageusia, dysgeusia, oral hypoaesthesia, nausea, somnolence, and taste disorders.

CONCLUSIONS

Gefapixant, while generally well tolerated, did not reduce OSA severity in patients with chemoreflex-dependent OSA. P2X3 receptor antagonism is unlikely to provide an avenue for therapeutic intervention in OSA.

CLINICAL TRIAL REGISTRATION: Registry: ClinicalTrials.gov; Name: Safety and Tolerability of Gefapixant (MK-7264) in Participants with Obstructive Sleep Apnea (MK-7264-039); URL: https://clinicaltrials.gov/study/NCT03882801; Identifier: NCT03882801.

CITATION: Robbins JA, Sands S, Maganti L, et al. Gefapixant as a P2X3 receptor antagonist treatment for obstructive sleep apnea: a randomized controlled trial. J Clin Sleep Med. 2024;20(12):1905-1913.

Для цитирования: Robbins Jonathan A, Sands Scott, Maganti Lata, Crumley Tami, Fox-Bosetti Sabrina, Hussain Azher, Schwartz Howard, Safirstein Beth, Ahmad Maha, Dragone Leonard, Nussbaum Jesse, Kushida Clete, Iwamoto Marian, Stoch S Aubrey. Gefapixant as a P2X3 receptor antagonist treatment for obstructive sleep apnea: a randomized controlled trial.. Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine. 2024. DOI: 10.5664/jcsm.11272.