Determination of exposure of dispensary drug preparers to cyclophosphamide by passive sampling and liquid chromatography with tandem mass spectrometry.

Wakui Nobuyuki, Ookubo Tetuo, Iwasaki Yusuke, Ito Rie, Mitui Miyuki, Yano Yuichi, Saito Koichi, Nakazawa Hiroyuki

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To determine cyclophosphamide exposure to preparers during tablet crushing and subsequent handling by analyzing indoor air collected using a high-performance volatile organic compounds-solvent desorption (VOC-SD) passive air sampler.

METHODS

The passive sampler was taped to the mask over the mouth of the preparer and indoor air was collected during crushing and preparation of cyclophosphamide tablets (Endoxan®). After collection, the carbon molecular sieve adsorbent of the passive sampler was placed in a centrifuge tube, and 1 mL of carbon disulfide was used to elute cyclophosphamide from the adsorbent. Liquid-liquid extraction with 1 mL of water was performed, and the aqueous phase was used as the test solution. Cyclophosphamide concentration was determined by liquid chromatography with ultraviolet and tandem mass spectrometry detection.

RESULTS

Cyclophosphamide concentration was detected in the range of 7.6-157.7 ng/sampler. Our results showed that low-level exposure occurred near the mouth of the preparer, which could present risks for long-term exposure, especially if combined with multiple toxic drug exposures.

CONCLUSION

The anticancer drug monitoring methodology described here is a simple exposure assessment that can be used to ensure the safety of hospital pharmacy tablet preparers. Furthermore, since the anticancer drug exposure risk is very high for preparers, preparation should be in hood or with face mask.

Для цитирования: Wakui Nobuyuki, Ookubo Tetuo, Iwasaki Yusuke, Ito Rie, Mitui Miyuki, Yano Yuichi, Saito Koichi, Nakazawa Hiroyuki. Determination of exposure of dispensary drug preparers to cyclophosphamide by passive sampling and liquid chromatography with tandem mass spectrometry.. Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners. 2012. DOI: 10.1177/1078155212451196.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.