MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s40477-023-00847-8

Медицинская библиотека · Journal of ultrasound · 2024

Value of painless transvaginal four-dimensional hysterosalpingo contrast sonography in reducing venous intravasation: a comparative study.

Chen Mengjie, Huang Shiying, Song Changlin, Chen Xiaomin, Chen Jiajia, Bu Guojuan, Zhang Huiying, Huang Wanling, Fu Juan, Xu Erjiao

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

To investigate the value of painless transvaginal four-dimensional hysterosalpingo contrast sonography (TV 4-D HyCoSy) in reducing venous intravasation and its influencing factors through a retrospective comparative study on conventional TV 4-D HyCoSy.

MATERIALS AND

METHODS

A total of 451 patients were enrolled in this study from Jan. 2019 to Oct. 2021. There were 249 patients in the painless TV 4-D HyCoSy group and 202 patients in the conventional TV 4-D HyCoSy group. The incidence of venous intravasation and its related influencing factors were analyzed and compared between these two groups. The difficulty of image evaluation for the diagnosis was also compared.

RESULTS

There was no significant difference in the baseline characteristics between the painless group and the conventional group (p > 0.05). Compared with the conventional group, the painless group had a lower incidence of venous intravasation (16.9 vs. 24.8%; p = 0.039). Painless TV 4-D HyCoSy was more effective in reducing venous intravasation in patients with primary infertility (p = 0.032) without a history of pelvic surgery (p = 0.008) or ectopic pregnancy (p = 0.018). Logistic regression analysis demonstrated that painless TV 4-D HyCoSy and endometrial thickness > 5 mm were protective factors for venous intravasation. Moreover, the diagnostic procedure was easier in the painless group than in the conventional group (p = 0.002).

CONCLUSIONS

Painless TV 4D-HyCoSy may be an effective mode in reducing the incidence of venous intravasation and improving the diagnosis of patency of fallopian tubes.

Для цитирования: Chen Mengjie, Huang Shiying, Song Changlin, Chen Xiaomin, Chen Jiajia, Bu Guojuan, Zhang Huiying, Huang Wanling, Fu Juan, Xu Erjiao. Value of painless transvaginal four-dimensional hysterosalpingo contrast sonography in reducing venous intravasation: a comparative study.. Journal of ultrasound. 2024. DOI: 10.1007/s40477-023-00847-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.