MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pone.0284792

Медицинская библиотека · PloS one · 2023

Surfactant delivery via thin catheter in preterm infants: A systematic review and meta-analysis.

Yeung Telford Y, Zhou Qi, Kanmaz Kutman H Godze, Pandita Aakash, Philippopoulos Eleni, Jasani Bonny

МетаанализСистематический обзорСтатьяПеревод в очереди

Аннотация

OBJECTIVE

Surfactant administration via a thin catheter (STC) is an alternative to surfactant administration post endotracheal intubation in preterm infants with respiratory distress syndrome (RDS); however, the benefits particularly in infants <29 weeks' gestation and the neurodevelopmental outcomes remain unclear. Thus, our objective was to systematically review and meta-analyze the efficacy and safety of STC compared to intubation for surfactant or nasal continuous positive airway pressure (nCPAP) in preterm infants with RDS.

METHODS

Medical databases were searched until December 2022 for randomized controlled trials (RCTs) assessing STC compared to controls that included intubation for surfactant or nCPAP in preterm infants with RDS. The primary outcome was bronchopulmonary dysplasia (BPD) at 36 weeks gestation in survivors. Subgroup analysis was conducted comparing STC to controls in infants < 29 weeks' gestation. The Cochrane risk of bias (ROB) tool was used and certainty of evidence (CoE) was rated according to GRADE.

RESULTS

Twenty-six RCTs of 3349 preterm infants, in which half of the studies had low risk of bias, were included. STC decreased the risk of BPD in survivors compared to controls (17 RCTs; N = 2408; relative risk (RR) = 0.66; 95% confidence interval (CI) 0.51 to 0.85; number needed to treat for an additional beneficial outcome (NNTB) = 13; CoE: moderate). In infants < 29 weeks' gestation, STC significantly reduced the risk of BPD compared to controls (6 RCTs, N = 980; RR 0.63; 95% CI 0.47 to 0.85; NNTB = 8; CoE: moderate).

CONCLUSIONS

Compared to controls, STC may be a more efficacious and safe method of surfactant delivery in preterm infants with RDS, including infants < 29 weeks' gestation.

Для цитирования: Yeung Telford Y, Zhou Qi, Kanmaz Kutman H Godze, Pandita Aakash, Philippopoulos Eleni, Jasani Bonny. Surfactant delivery via thin catheter in preterm infants: A systematic review and meta-analysis.. PloS one. 2023. DOI: 10.1371/journal.pone.0284792.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.