Physiological Responses to Sit-to-Stand and Six-Minute Walk Tests in Heart Failure: A Randomised Trial.

O'Connor Fergus K, Chen Dongyi, Sharma Pramod, Adsett Julie, Hwang Rita, Roberts Llion, Bach Aaron, Louis Menaka, Morris Norman

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Short-duration sit-to-stand tests are utilised in rehabilitation settings to alleviate logistical challenges associated with the six-minute walk test (6MWT). We assessed the utility of the 30-second sit-to-stand (30-STST) and 60-second sit-to-stand (60-STST) tests as surrogate measures of the 6MWT.

METHOD: On separate days, 16 male participants (71 [7] years) with stable heart failure with reduced ejection fraction (36.9 [4.9] %) completed two 6MWT and the 30-STST and 60-STST. Pulmonary gas exchange (oxygen consumption, carbon dioxide production [V˙CO2], ventilation [V˙E], respiratory exchange ratio, ventilatory equivalent for CO2 [V˙E/V˙CO2] and partial pressure of end-tidal CO2 [PETCO2]) was measured using a portable metabolic system. Non-invasive haemodynamics (cardiac output, stroke volume, arteriovenous oxygen difference) were measured using impedance cardiography. Mean arterial pressure, heart rate, oxygen saturation and dyspnoea (0-10 scale, arbitrary units) were also monitored. Mixed-effects models (Bonferroni corrected) accounting for time (pre-exercise rest, end-exercise) and test (6MWT, 30-STST, and 60-STST) were used to assess the relation between results observed during each testing modality.

RESULTS

While PETCO2 (mean difference [95% confidence interval], -4.9 [-8.9 to -0.8] mmHg), and dyspnoea (1 [0-2] arbitrary units) differed between the 6MWT and 60-STST, no other differences were observed between these tests. In contrast, oxygen consumption (-0.5 [-0.6 to -0.3] L.min-1), V˙CO2 (-0.5 [-0.7 to -0.4] L.min-1), V˙E (-18.3 [-26.0 to -10.0] L.min-1), PETCO2 (-5.1 [-9.6 to -0.7] mmHg), cardiac output (-2.4 [-4.9 to -0.3] L.min-1), heart rate (-20 [-33 to -7] beats/min) differed between the 6MWT and the 30-STST, however, no other differences were observed between the 6MWT and the 30-STST.

CONCLUSIONS

Cardiopulmonary, non-invasive haemodynamic and dyspnoea responses differed between the 30-STST and the 6MWT. However, the lack of test-specific differences between the 6MWT and the 60-STST highlights the strong physiological stimulus elicited by this short-duration test modality. The 60-STST has promising utility as a functional measure of heart and lung capacity within cardiac rehabilitation programs.

Для цитирования: O'Connor Fergus K, Chen Dongyi, Sharma Pramod, Adsett Julie, Hwang Rita, Roberts Llion, Bach Aaron, Louis Menaka, Morris Norman. Physiological Responses to Sit-to-Stand and Six-Minute Walk Tests in Heart Failure: A Randomised Trial.. Heart, lung & circulation. 2025. DOI: 10.1016/j.hlc.2025.03.002.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.