MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40634-020-00279-x

Медицинская библиотека · Journal of experimental orthopaedics · 2020

Does the choice of syndesmotic screw versus suture button in ankle surgery has a silver lining? - a technical note.

D'Hooghe Pieter, Salameh Motasem

СтатьяПеревод в очереди

Аннотация

PURPOSE: Unstable ankle fractures with associated syndesmotic injury are of considerable morbidity in the professional athlete population. The use of dynamic suture button versus static syndesmotic screws fixation, rehabilitation protocols and timing to return to play are still areas of debate. We report the use of novel algorithm of sequential static and dynamic syndesmotic fixation in an elite football player with Weber C ankle fracture.

METHODS

The patient underwent open reduction and internal fixation for a weber C ankle fracture with associated syndesmotic and deltoid ligament injury. The osteosynthesis included lateral malleolus neutralizing plate, two syndesmotic screws and deltoid anchor repair. At 6 weeks post-operative both syndesmotic screws were removed and one suture button was implanted in the proximal screw hole. After the second operation the patient was allowed full weight bearing and range of motion in all direction with accelerated rehabilitation protocol.

RESULTS

The technique provided satisfactory results. At 4 month the player participated in a 90 min official football match. The fracture healed uneventfully with no recurrent syndesmotic diastasis.

CONCLUSION

The presented technique of sequential dynamic and static fixation of associated syndesmotic injuries combined advantages of both syndesmotic screws and suture button implants. In an aim to allow earlier return to play in an elite football player. This opens the way for higher level of evidence clinical trials.

Для цитирования: D'Hooghe Pieter, Salameh Motasem. Does the choice of syndesmotic screw versus suture button in ankle surgery has a silver lining? - a technical note.. Journal of experimental orthopaedics. 2020. DOI: 10.1186/s40634-020-00279-x.