MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsabm.3c00613

Медицинская библиотека · ACS applied bio materials · 2023

Rod-Shaped Spinel Co3O4 and Carbon Nitride Heterostructure-Modified Fluorine-Doped Tin Oxide Electrode as an Electrochemical Transducer for Efficient Sensing of Hydrazine.

Ramesh Asha, Maladan Aswathi, Sahu Pravat Kumar, Duvvuri Suryakala, Subrahmanyam Ch

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Engineering low-cost and efficient materials for sensing hydrazine (HA) is critical given the adverse effects of high concentrations on humans. We report an efficient electrode made up of rod-shaped Co3O4/g-C3N4 (Co3O4/graphitic carbon nitride (GCN))-coated fluorine-doped tin oxide as a desirable electrode for the detection of HA. GCN is synthesized by the thermal decomposition of melamine, Co3O4, and the heterostructure is grown by a hydrothermal process. The as-prepared materials were characterized by using spectroscopic and microscopic techniques. The voltammetric studies showed that HA can be oxidized at a lower onset potential of 0.24 V vs reference Ag/AgCl, and the composite yielded a significantly enhanced oxidation peak current than the pure components because of the high electrocatalytic activity and the synergy between Co3O4 and GCN. By employing chronoamperometry, the proposed sensor can detect HA in a wide range with a high sensitivity of 819.52 μA mM-1 cm-2 and a detection limit of 3.14 μM. The high conductivity of Co3O4, enhanced electroactive surface area, the rich redox couples of Co2+/Co3+, and the additional catalytic sites from GCN are responsible for the high performance of the heterostructure.

Для цитирования: Ramesh Asha, Maladan Aswathi, Sahu Pravat Kumar, Duvvuri Suryakala, Subrahmanyam Ch. Rod-Shaped Spinel Co3O4 and Carbon Nitride Heterostructure-Modified Fluorine-Doped Tin Oxide Electrode as an Electrochemical Transducer for Efficient Sensing of Hydrazine.. ACS applied bio materials. 2023. DOI: 10.1021/acsabm.3c00613.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.