MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijcard.2023.131203

Медицинская библиотека · International journal of cardiology · 2023

Thoracic aorta diameters in Marfan patients: Intraindividual comparison of 3D modified relaxation-enhanced angiography without contrast and triggering (REACT) with transthoracic echocardiography.

Gietzen Carsten, Pennig Lenhard, von Stein Jennifer, Guthoff Henning, Weiss Kilian, Gertz Roman, Thürbach Iris, Bunck Alexander C, Maintz David, Baldus Stephan, Ten Freyhaus Henrik, Hohmann Christopher, von Stein Philipp

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To compare the measurement of aortic diameters using a novel flow-independent MR-Angiography (3D modified Relaxation-Enhanced Angiography without Contrast and Triggering (modified REACT)) and transthoracic echocardiography (TTE) in Marfan syndrome (MFS) patients.

MATERIAL AND

METHODS

This retrospective, single-center analysis included 46 examinations of 32 MFS patients (mean age 37.5 ± 11.3 years, 17 women, no prior aortic surgery) who received TTE and 3D modified REACT (ECG- and respiratory-triggering, Compressed SENSE factor 9 for acceleration of image acquisition) of the thoracic aorta. Aortic diameters (sinus of Valsalva (SV), sinotubular junction (STJ), and ascending aorta (AoA)) were independently measured by two cardiologists in TTE (leading-edge) and two radiologists in modified REACT (inner-edge, using multiplanar reconstruction). Intraclass correlation coefficient, Bland-Altman analyses, and Pearson's correlation (r) were used to assess agreement between observers and methods.

RESULTS

Interobserver correlation at the SV, STJ, and AoA were excellent for both, TTE (ICC = 0.95-0.98) and modified REACT (ICC = 0.99-1.00). There was no significant difference between TTE and modified REACT for diameters measured at the SV (39.24 ± 3.24 mm vs. 39.63 ± 3.76 mm; p = 0.26; r = 0.78) and the STJ (35.16 ± 4.47 mm vs. 35.37 ± 4.74 mm; p = 0.552; r = 0.87). AoA diameters determined by TTE were larger than in modified REACT (34.29 ± 5.31 mm vs. 30.65 ± 5.64 mm; p < 0.01; r = 0.74). The mean scan time of modified REACT was 05:06 min ± 02:47 min, depending on the patient's breathing frequency and heart rate.

CONCLUSIONS

Both TTE and modified REACT showed a strong correlation for all aortic levels; however, at the AoA, diameters were larger using TTE, mostly due to the limited field of view of the latter with measurements being closer to the aortic valve. Given the excellent interobserver correlation and the strong agreement with TTE, modified REACT represents an attractive method to depict the thoracic aorta in MFS patients.

Для цитирования: Gietzen Carsten, Pennig Lenhard, von Stein Jennifer, Guthoff Henning, Weiss Kilian, Gertz Roman, Thürbach Iris, Bunck Alexander C, Maintz David, Baldus Stephan, Ten Freyhaus Henrik, Hohmann Christopher, von Stein Philipp. Thoracic aorta diameters in Marfan patients: Intraindividual comparison of 3D modified relaxation-enhanced angiography without contrast and triggering (REACT) with transthoracic echocardiography.. International journal of cardiology. 2023. DOI: 10.1016/j.ijcard.2023.131203.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.