MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.fertnstert.2022.07.005

Медицинская библиотека · Fertility and sterility · 2022

Outpatient hysteroscopic removal of intrauterine devices in early pregnancy: feasibility and outcomes.

Jaber Sireen, Gilad Ronit, Bauman Dvora, Levin Gabriel, Voss Ernst

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To describe our experience with outpatient hysteroscopy for removal of intrauterine devices (IUDs) in pregnant patients, along with the pregnancy-related outcomes.

DESIGN

Retrospectively and prospectively collected data between January 2015 and April 2021.

SETTING

Hysteroscopic outpatient clinic (See and Treat Clinic) at a university affiliated, tertiary medical center.

PATIENT(S): Forty-one patients with an inadvertent but desired pregnancy up to 12 weeks + 6 days gestational age with an IUD in situ, with documented failed attempts of IUD removal.

INTERVENTION(S): After ultrasonographic confirmation of IUD location, gestational age, and viability, a small-caliber hysteroscope was introduced via a vaginoscopic approach. The uterus was distended using 0.9% normal saline until a clear view was achieved. On visualization, the IUD was grasped by its strings, tail, or lateral arm using a semirigid hysteroscopic grasper. Oral antibiotic prophylaxis was prescribed in all cases.

MAIN OUTCOME MEASURE(S): The primary outcome of interest was term delivery, from 37 weeks of gestation. Secondary outcomes included patient-reported tolerability and satisfaction, and procedure-related and pregnancy related complications.

RESULT(S): The procedure was completed successfully in all 41 patients. Thirty-three patients continued their pregnancies, resulting in 32 full-term singleton deliveries and 1 singleton preterm delivery at 33 + 4 weeks. Median gestational age at delivery was 39 weeks, with a median birthweight of 3,450 grams. Eight patients (19.5%) miscarried, 4 of these within a week of the procedure.

CONCLUSION(S): In cases of desired pregnancy with an IUD, outpatient hysteroscopic removal of the IUD is a safe and effective management option. Broader uptake of outpatient hysteroscopy and development of hysteroscopic skills will allow more clinicians to offer patients this effective solution.

Для цитирования: Jaber Sireen, Gilad Ronit, Bauman Dvora, Levin Gabriel, Voss Ernst. Outpatient hysteroscopic removal of intrauterine devices in early pregnancy: feasibility and outcomes.. Fertility and sterility. 2022. DOI: 10.1016/j.fertnstert.2022.07.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.