MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.maturitas.2024.108188

Медицинская библиотека · Maturitas · 2024

Feasibility of digital phenotyping based on continuous glucose monitoring to support personalized lifestyle medicine in type 2 diabetes.

van den Brink Willem J, van den Broek Tim J, Wopereis Suzan, Difrancesco Sonia, van der Horst Frans A L, de Hoogh Iris M

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

Type 2 diabetes is a highly prevalent age-related chronic condition, with complex and heterogeneous pathogenesis. A 5-point oral glucose tolerance test can identify type 2 diabetes subtypes or "diabetypes" based on the degree of insulin resistance in muscle and/or liver, and beta-cell dysfunction. Due to its costly and invasive nature, the oral glucose tolerance test is not scalable. Presuming that differences in glucose and insulin dynamics manifest in continuous glucose monitoring profiles, we explore the potential of continuous glucose metrics to replace the oral glucose tolerance test for diabetyping.

STUDY

DESIGN

In a prospective intervention study, 41 people with type 2 diabetes on lifestyle and/or metformin treatment wore a continuous glucose monitor during 3 control periods of 4 days. During each control period, participants underwent a 5-point oral glucose tolerance test after an overnight fast.

MAIN OUTCOME MEASURES: Continuous glucose monitoring data from the control periods, excluding the day of the oral glucose tolerance test, was retrospectively analyzed for associations with diabetypes, as well as Spearman correlations between bootstrapped continuous glucose features, including physiology-based and other time-series features, and oral glucose tolerance metrics.

RESULTS

Significant associations were observed between continuous glucose metrics (e.g., low and high blood glucose index, eA1c, and glucose excursions) and oral glucose tolerance metrics (e.g., 2-h glucose, disposition index, insulinogenic index). Furthermore, data-driven metrics (e.g., maximum shift, lumpiness) showed more selective correlations, indicating that data-driven metrics may contain additional information associated with oral glucose tolerance metrics.

CONCLUSIONS

These results indicate the potential of continuous glucose monitoring to replace the oral glucose tolerance test for diabetyping, driving proactive and personalized (lifestyle) treatment.

NETHERLANDS TRIAL REGISTER: NL7848.

Для цитирования: van den Brink Willem J, van den Broek Tim J, Wopereis Suzan, Difrancesco Sonia, van der Horst Frans A L, de Hoogh Iris M. Feasibility of digital phenotyping based on continuous glucose monitoring to support personalized lifestyle medicine in type 2 diabetes.. Maturitas. 2024. DOI: 10.1016/j.maturitas.2024.108188.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.