Direct retrieval of posteriorly dislocated intraocular lenses via limbal air bubble technique.
Аннотация
PURPOSE: To introduce a limbal-based technique for retrieving posteriorly dislocated IOLs without pars plana vitrectomy, utilizing an anterior chamber air bubble for fundus visualization.
METHODS
In this retrospective study, 3 limbal paracentesis incisions (2, 6, and 10 o'clock) were created in 9 eyes. An air bubble was injected into the anterior chamber to enable direct fundus visualization. The dislocated IOL was grasped via a forceps inserted through limbal incisions and repositioned or exchanged without pars plana vitrectomy.
RESULTS
9 patients (9 eyes) with posteriorly dislocated IOLs were enrolled in this retrospective study. In all cases, the dislocated IOLs were successfully elevated to the anterior segment. Among them, 7 IOLs were rescued and 2 were exchanged. No complications were observed, except for temporary high intraocular pressure in two cases immediately after the operation. No IOL redislocation was observed during a mean follow-up of 12 months.
CONCLUSION
Retrieving a posteriorly dislocated IOL through a limbal approach utilizing an anterior chamber air bubble is an efficient, safe, cost-effective, and easily accessible technique.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.