British journal of clinical pharmacology · 1999
Pharmacokinetics of chlorofluorocarbon and hydrofluoroalkane metered-dose inhaler formulations of beclomethasone dipropionate.
Клиническое исследованиеСравнительное исследованиеСтатьяРандомизированное исследованиеПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lipworth B J, Jackson C M
Аннотация
AIMS: To compare the pharmacokinetic profile of Beclazone (beclomethasone dipropionate) in its chlorofluorocarbon (CFC)-based and CFC-free formulations.
METHODS: Ten healthy adults received a single 1,000 microg nominal dose (ex-valve) of beclomethasone dipropionate from a CFC inhaler (BEC-CFC) or from a CFC-free inhaler containing hydrofluoroalkane (HFA)-134a (BEC-HFA) in an open-label, randomized, two-way, crossover study. Blood samples were collected predose and over 12 h after inhalation. Comparisons were made of maximum plasma concentration of beclomethasone 17-monopropionate (17-BMP) (Cmax), and area under the plasma concentration vs time curve (AUC).
RESULTS: The tmax was significantly (P<0.05) earlier with BEC-HFA and plasma levels were significantly higher following administration of BEC-HFA than BEC-CFC. Geometric mean values for AUC were 1.5 fold greater (90% CI 1.3-1.9) and for Cmax were 1.9 fold greater (90% CI 1.6-2.6) following BEC-HFA than BEC-CFC.
CONCLUSIONS: Our data in healthy volunteers would not be consistent with the manufacturers' recommendation for a microgram equivalent (1:1) nominal dose switch between these HFA and CFC formulations. Further well designed trials are required in asthmatic patients to properly define their respective dose-response relationships for antiasthmatic and systemic adverse effects.
METHODS: Ten healthy adults received a single 1,000 microg nominal dose (ex-valve) of beclomethasone dipropionate from a CFC inhaler (BEC-CFC) or from a CFC-free inhaler containing hydrofluoroalkane (HFA)-134a (BEC-HFA) in an open-label, randomized, two-way, crossover study. Blood samples were collected predose and over 12 h after inhalation. Comparisons were made of maximum plasma concentration of beclomethasone 17-monopropionate (17-BMP) (Cmax), and area under the plasma concentration vs time curve (AUC).
RESULTS: The tmax was significantly (P<0.05) earlier with BEC-HFA and plasma levels were significantly higher following administration of BEC-HFA than BEC-CFC. Geometric mean values for AUC were 1.5 fold greater (90% CI 1.3-1.9) and for Cmax were 1.9 fold greater (90% CI 1.6-2.6) following BEC-HFA than BEC-CFC.
CONCLUSIONS: Our data in healthy volunteers would not be consistent with the manufacturers' recommendation for a microgram equivalent (1:1) nominal dose switch between these HFA and CFC formulations. Further well designed trials are required in asthmatic patients to properly define their respective dose-response relationships for antiasthmatic and systemic adverse effects.