Ability of Dual-Energy CT to Detect Silicone Gel Breast Implant Rupture and Nodal Silicone Spread.

Glazebrook Katrina N, Doerge Stefan, Leng Shuai, Drees Tammy A, Hunt Katie N, Zingula Shannon N, Pruthi Sandhya, Geske Jennifer R, Carter Rickey E, McCollough Cynthia H, Fletcher Joel G

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

The purpose of this study is to compare the performance of dual-energy CT (DECT) with that of breast MRI for detection of silicone gel breast implant rupture and nodal spread of silicone.

SUBJECTS AND

METHODS

This prospective study enrolled consecutive patients with current or prior silicone gel implants and clinical suspicion of implant rupture or extra-capsular silicone. All patients underwent MRI followed by unenhanced DECT. A breast radiologist not participating in image evaluation established reference standards for implant rupture (intra- or extracapsular) and regional nodal silicone spread (to axillary nodes and internal mammary [IM] and mediastinal nodes) using MRI, surgical findings, and medical records. After undergoing reader training, two radiologists who were blinded to all medical records interpreted randomized images in two sessions, indicating confidence in diagnosis using a 100-point visual scale.

RESULTS

A total of 46 patients who had a subpectoral silicone gel implant (n = 31), a subglandular silicone gel implant (n = 14), or a silicone gel implant that was removed (n = 1) underwent MRI and DECT (mean [± SD] volume CT dose index, 8.2 ± 2.0 mGy). Nineteen patients had implant rupture, and 13 of these patients had silicone within the IM or axillary nodes. Pooled data showed no significant difference between MRI and DECT interpretation of intra- or extracapsular rupture of implants (AUC value for intracapsular rupture, 0.958 [for MRI] vs 0.989 [for DECT]; p = 0.28; AUC value for extracapsular rupture, 0.864 [for MRI] vs 0.878 [for DECT]; p = 0.78). No difference was noted in the AUC value for silicone spread to regional lymph nodes: 0.823-0.866 [for MRI] vs 0.892-0.906 [for DECT]; p = 0.34-0.54).

CONCLUSION

DECT performs similar to MRI for the detection of silicone gel implant rupture and the presence of silicone in regional lymph nodes, and it may be an alternative for patients who are unable or unwilling to undergo MRI.

Для цитирования: Glazebrook Katrina N, Doerge Stefan, Leng Shuai, Drees Tammy A, Hunt Katie N, Zingula Shannon N, Pruthi Sandhya, Geske Jennifer R, Carter Rickey E, McCollough Cynthia H, Fletcher Joel G. Ability of Dual-Energy CT to Detect Silicone Gel Breast Implant Rupture and Nodal Silicone Spread.. AJR. American journal of roentgenology. 2019. DOI: 10.2214/ajr.18.20138.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.