MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Bollettino della Societa italiana di biologia sperimentale · 1999

Nocturnal oxygen desaturation in patients with congestive heart failure.

Resta O, Foschino-Barbaro M P, Bonfitto P G, Talamo S, Nocerino M C, Stefà no A, Biasco G

СтатьяПеревод в очереди

Аннотация

The aim of our study was to evaluate the modifications of the respiratory pattern during sleeping in patients with congestive heart failure (CHF) by a simple pulse-oxymetry. We studied 10 subjects (8M/2F), mean age 71.4 +/- 12.4 yrs, admitted to sub-intensive cardiological therapy unit, with diagnosis of CHF due to left ventricular insufficiency by ischemic, hypertensive or idiopathic cardiopathy, when in a stable clinical condition. All patients presented arterial blood gas values within normal limits. The ejection fraction of left ventricle showed a mean value of 30.4 +/- 8.2% (range 20%-45%). Nocturnal pulse-oxymetry was performed by pulse-oxymeter (PULSOX 7 Minolta) provided with a digital probe at a sliding speed 24 cm/h. Our data showed that all patients presented nocturnal desaturation episodes (mean oxygen desaturation index 15.7 +/- 18.4). In two patients, we found an "Overlap Syndrome" (obstructive sleep apnoea in presence of cardiopathy). In other patients pulse-oxymetry showed a typical sequence of "fall-rise" basal O2 saturation lasting from 36 to 72 seconds, collected in "wave trains" which were present from 14% to 70% of total sleep time compatible with periodic breathing. In conclusion, our study shows that patients affected by CHF, even if in stable condition and with a PaO2, within normal values, present more or less severe disturbances of nocturnal SaO2, with periodic and regular sequences of SaO2 fall-rise that may be referred to ventilatory troubles such as periodic breathing or Cheyne-Stokes breathing. In these patients the pulse-oxymetry may be considered an efficacious, simple, cheap and well tolerated method.

Для цитирования: Resta O, Foschino-Barbaro M P, Bonfitto P G, Talamo S, Nocerino M C, Stefà no A, Biasco G. Nocturnal oxygen desaturation in patients with congestive heart failure.. Bollettino della Societa italiana di biologia sperimentale. 1999.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.