MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0034-7094(11)70072-1

Медицинская библиотека · Revista brasileira de anestesiologia · 2011

Use of a minimally invasive uncalibrated cardiac output monitor in patients undergoing cesarean section under spinal anesthesia: report of four cases.

Bliacheriene Fernando, Carmona Maria José Carvalho, Barretti Cristina de Freitas Madeira, Haddad Cristiane Maria Federicci, Mouchalwat Elaine Soubhi, Bortolotto Maria Rita de Figueiredo Lemos, Francisco Rossana Pulcineli Vieira, Zugaib Marcelo

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND AND

OBJECTIVES

Hemodynamic changes are observed during cesarean section under spinal anesthesia. Non-invasive blood pressure (BP) and heart rate (HR) measurements are performed to diagnose these changes, but they are delayed and inaccurate. Other monitors such as filling pressure and cardiac output (CO) catheters with external calibration are very invasive or inaccurate. The objective of the present study was to report the cardiac output measurements obtained with a minimally invasive uncalibrated monitor (LiDCO rapid) in patients undergoing cesarean section under spinal anesthesia.

CASE REPORT: After approval by the Ethics Commission, four patients agreed to participate in this study. They underwent cesarean section under spinal anesthesia while at the same time being connected to the LiDCO rapid by a radial artery line. Cardiac output, HR, and BP were recorded at baseline, after spinal anesthesia, after fetal and placental extraction, and after the infusion of oxytocin and metaraminol. We observed a fall in BP with an increase of HR and CO after spinal anesthesia and oxytocin infusion; and an increase in BP with a fall in HR and CO after bolus of the vasopressor.

CONCLUSIONS

Although this monitor had not been calibrated, it showed a tendency for consistent hemodynamic data in obstetric patients and it may be used as a therapeutic guide or experimental tool.

Для цитирования: Bliacheriene Fernando, Carmona Maria José Carvalho, Barretti Cristina de Freitas Madeira, Haddad Cristiane Maria Federicci, Mouchalwat Elaine Soubhi, Bortolotto Maria Rita de Figueiredo Lemos, Francisco Rossana Pulcineli Vieira, Zugaib Marcelo. Use of a minimally invasive uncalibrated cardiac output monitor in patients undergoing cesarean section under spinal anesthesia: report of four cases.. Revista brasileira de anestesiologia. 2011. DOI: 10.1016/s0034-7094(11)70072-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.