MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.ico.0000226366.64796.20

Медицинская библиотека · Cornea · 2006

Randomized, double-masked clinical trial evaluating corneal endothelial cell loss after cataract extraction and intraocular lens implantation: Fluid-based system versus ultrasound phacoemulsification.

Sandoval Helga P, de Castro Luis E Fernández, Vroman David T, Solomon Kerry D

СтатьяРандомизированное исследованиеПоддержка NIH: внешняя программаПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To assess the endothelial cell loss after cataract extraction using a fluid-based system and compare it with conventional ultrasound.

METHODS

A total of 46 eyes of 23 patients with up to 3+ bilateral cataract were included. The first eye was randomized to either fluid-based system or conventional ultrasound, and the fellow eye received the alternate system. Visual acuity and ultrasound pachymetry were measured preoperatively and at 1 day, 1 week, and 1 and 3 months postoperatively. Specular microscopy was performed preoperatively and 3 months after the surgery. Data was analyzed using the paired t test and Wilcoxon signed rank test. A P value less than 0.05 was considered statistically significant.

RESULTS

Postoperatively, no significant differences were found among the groups. However, there was a significant difference (P < 0.01, analysis of variance with Tukey as posttest) in corneal pachymetry at day 1 after the surgery compared with baseline in both groups. There was a 6.3% and 7.9% loss of endothelial cells in the fluid-based system and ultrasound group, respectively.

CONCLUSION

Visual acuity, pachymetry, and endothelial cell loss after cataract extraction and intraocular lens implantation using a fluid-based system is similar to conventional ultrasound.

Для цитирования: Sandoval Helga P, de Castro Luis E Fernández, Vroman David T, Solomon Kerry D. Randomized, double-masked clinical trial evaluating corneal endothelial cell loss after cataract extraction and intraocular lens implantation: Fluid-based system versus ultrasound phacoemulsification.. Cornea. 2006. DOI: 10.1097/01.ico.0000226366.64796.20.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.