MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.injury.2023.111214

Медицинская библиотека · Injury · 2023

3D-navigation for SI screw fixation - How does it affect radiation exposure for patients and medical personnel?

Kalbas Yannik, Hoch Yannis, Klingebiel Felix Karl-Ludwig, Klee Octavia, Cester Davide, Halvachizadeh Sascha, Berk Till, Wanner Guido A, Pfeifer Roman, Pape Hans-Christoph, Hasler Rebecca Maria

СтатьяПеревод в очереди

Аннотация

BACKGROUND

3D-navigation for percutaneous sacroiliac (SI) screw fixation is becoming increasingly common and several studies report great advantages of this technology. However, there is still limited clinical evidence on the efficacy regarding radiation exposure for patient and personnel.

METHODS

This is a retrospective, single-center cohort study. All patients who underwent percutaneous sacroiliac screw fixation for an injury of the posterior pelvic ring from 2014 to 2021 were screened. Inclusion criteria were: conclusive radiation dosage reports, signed informed consent, a twelve month follow up and a complete data set. Patients were stratified in two groups (3D-navigation (Group 3D-N) vs. control (Group F)) based on the imaging modality used. Primary outcomes were radiation exposure for patient and personnel. Secondary outcomes were reoperations, complications, and intraoperative precision.

RESULTS

Of 392 patients screened, 174 patients (3D-N: n = 50, F: n = 124) could be included for final analysis. We noted a significant reduction of the dose corresponding to potential radiation exposure for medical personnel (-15.3 mGy, 95 %CI: -2.1 to -28.5, p = 0.0232), but also a significant increase of the dose quantifying radiation exposure for patients (+77.0 mGy, 95 %CI: +53.3 to +100.6, p < 0.0001), when using navigation. In addition, the rate of radiographic malplacement was significantly reduced (F: 11.3% vs. 3D-N: 0 %, p = 0.0113) despite a substantial increase in transsacral screw placement (F: 19.4% vs. 3D-N: 76 %).

CONCLUSION

Our data clearly suggests that the use of 3D-navigation for percutaneous SI screw fixation decreases radiation exposure for medical personnel, while increasing radiation exposure for patients. Furthermore, intraoperative precision is improved, even in more challenging operations.

Для цитирования: Kalbas Yannik, Hoch Yannis, Klingebiel Felix Karl-Ludwig, Klee Octavia, Cester Davide, Halvachizadeh Sascha, Berk Till, Wanner Guido A, Pfeifer Roman, Pape Hans-Christoph, Hasler Rebecca Maria. 3D-navigation for SI screw fixation - How does it affect radiation exposure for patients and medical personnel?. Injury. 2023. DOI: 10.1016/j.injury.2023.111214.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.