MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.4c05488

Медицинская библиотека · Analytical chemistry · 2024

Dual-Response Functionalized Mitochondrial Fluorescent Probe for a Double Whammy Monitoring of Hypochlorite and Sulfur Dioxide in Heat Shock via Time Scales.

Cao Hongshuai, Yu Feifei, Dou Kun, Wang Rui, Xing Yanlong, Luo Xianzhu, Yu Fabiao

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Heat shock seriously affects the normal functioning of an organism and can lead to damage and even death in severe cases. To prevent or treat heat shock-related diseases, we require a better understanding of the mechanism of thermocytotoxicity. Here, we designed a functionalized dual-response fluorescent probe (HCy-SO2-HClO) that could individually or simultaneously detect hypochlorous acid (HClO) and sulfur dioxide (SO2) without interfering with each other and achieved the simultaneous tracing of both during the heat shock process for the first time. The introduction of the sulfonate group greatly increased the water solubility of the probe. Furthermore, the probe could effectively accumulate in the mitochondrial region. HCy-SO2-HClO could respond to HClO and SO2 within 10 s and 20 min, respectively, realizing a double whammy detection of both on the time scale. HCy-SO2-HClO exhibited high specificity and sensitivity for HClO and SO2. The highly biocompatible probe HCy-SO2-HClO successfully achieved the detection of endogenous and exogenous SO2 and HClO in living cells and in zebrafish. Moreover, the simultaneous detection of HClO and SO2 in heat shock cells and mouse intestines was realized for the first time. This probe has achieved the detection of dual markers, which enhanced the accuracy and precision of disease detection and could serve as an effective research tool to prevent heat stroke-related diseases.

Для цитирования: Cao Hongshuai, Yu Feifei, Dou Kun, Wang Rui, Xing Yanlong, Luo Xianzhu, Yu Fabiao. Dual-Response Functionalized Mitochondrial Fluorescent Probe for a Double Whammy Monitoring of Hypochlorite and Sulfur Dioxide in Heat Shock via Time Scales.. Analytical chemistry. 2024. DOI: 10.1021/acs.analchem.4c05488.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.