MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/bco2.287

Медицинская библиотека · BJUI compass · 2023

AdVance™ male sling for stress urinary incontinence: Long-term follow-up and patient satisfaction.

Boe Rebecca Therese, Nilsen Ole Jacob, Holm Henriette Veiby

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To evaluate long-term effects, complications and satisfaction among patients treated with AdVance™ and AdVance™ XP slings (AS) at a Norwegian specialist care hospital.

MATERIALS AND

METHODS

Patients who had an AS implanted due to stress urinary incontinence (SUI) 2009-2016 were identified retrospectively. Demographic and perioperative data were extracted from electronic patient files. We did a patient-reported outcome measure (PROM) survey with the Expanded Prostate Cancer Index Composite (EPIC-26) urinary domain and a Satisfaction Questionnaire (SQ) 2018-2020. Cure was defined as use of ≤1 pad/day.

RESULTS

The AS was implanted in 165 patients, mainly due to mild to moderate SUI (median leakage 112 g, range 13-589 g/24 h). Preoperative urodynamics showed mild detrusor overactivity (DO) in 11 patients. At 6-week follow-up, 148 patients (90%) were cured. The most common complication was urinary retention (N = 38), transient in 32 patients (range 1-42 days). Two patients were later operated with division of the sling due to persistent retention. During clinical follow-up of up to 12 years, 27 patients were reoperated due to persistent/recurrent incontinence. The PROM survey was sent to 125 patients and 115 (92%) replied at median 73 (20-134) months postoperatively. Ninety-one (79%) used ≤1 pads/day, 97 (85%) were satisfied, one patient-reported pain. Regression analyses showed that failure (>1 pad/day) was significantly associated with a higher amount of leakage preoperatively and at the 6-week follow-up. Total cure rate in the complete cohort was 64% at median 73 (20-134) months follow-up.

CONCLUSIONS

The AS shows good and persistent long-term results in patients with mild to moderate SUI. The only identified risk factor for long-term failure was higher amount of leakage preoperatively. The incidence of high body mass index (BMI), DO and previous radiotherapy was low and not significantly associated with failure but is still considered risk factors.

Для цитирования: Boe Rebecca Therese, Nilsen Ole Jacob, Holm Henriette Veiby. AdVance™ male sling for stress urinary incontinence: Long-term follow-up and patient satisfaction.. BJUI compass. 2023. DOI: 10.1002/bco2.287.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.