Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2004
Nasal ciliary beat after insertion of septo-valvular splints.
Клиническое исследованиеСтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Piatti G, Scotti A, Ambrosetti U
Аннотация
OBJECTIVE: At present, endonasal paraseptal splints are devices frequently employed in rhinosurgery. We evaluated the local tolerance of a newly shaped device, the Guastella/Mantovani splint (G/M-SVS), with respect to the physiological mechanism of mucociliary clearance.
STUDY DESIGN AND SETTING: The study involved 20 patients who underwent septoplasty and/or turbinoplasty or other nasal surgical procedures. A sample of ciliated cells was obtained by nasal brushing and was examined ex vivo to determine the ciliary beat frequency (CBF) and morphology, before and 15 days after surgery.
RESULTS: Before surgery the mean CBF was 10.87 Hz +/- 0.56 Hz and when splints were removed it was 10.25 Hz +/- 1.9 Hz. Morphological evaluation of the ciliary motion after surgery demonstrated a normal, coordinated beat.
CONCLUSIONS: The G/M-SVS does not appear to interfere with the physiological mechanism of mucociliary clearance since CBF remain within a normal range.
SIGNIFICANCE: This is the first study that demonstrates an optimal tolerability and safety of the septo-valvular splints on nasal mucosa.
STUDY DESIGN AND SETTING: The study involved 20 patients who underwent septoplasty and/or turbinoplasty or other nasal surgical procedures. A sample of ciliated cells was obtained by nasal brushing and was examined ex vivo to determine the ciliary beat frequency (CBF) and morphology, before and 15 days after surgery.
RESULTS: Before surgery the mean CBF was 10.87 Hz +/- 0.56 Hz and when splints were removed it was 10.25 Hz +/- 1.9 Hz. Morphological evaluation of the ciliary motion after surgery demonstrated a normal, coordinated beat.
CONCLUSIONS: The G/M-SVS does not appear to interfere with the physiological mechanism of mucociliary clearance since CBF remain within a normal range.
SIGNIFICANCE: This is the first study that demonstrates an optimal tolerability and safety of the septo-valvular splints on nasal mucosa.