Samways Jack W, Cheng Timothy, Chow Ji-Jian, Shun-Shin Matthew J, Ali Nadine, Keene Daniel, Howard James P, Naraen Akriti, Saleh Keenan, Kaza Nandita, Sharma Chet, Mohal Jagdeep S, Reddy Rohin K, Strocchi Marina, Niederer Steven A, Peters Nicholas S, Linton Nicholas W F, Kanagaratnam Prapa, Ng Fu Siong, Francis Darrel P, Whinnett Zachary I, Arnold Ahran D

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Biventricular pacing (BVP) delivered cardiac resynchronization therapy (CRT) modestly improves activation synchrony in patients with heart failure and left bundle branch block (LBBB) but can trigger ventricular arrhythmias. His bundle pacing (HBP) can correct LBBB as an alternative CRT method, producing superior ventricular activation synchrony and hemodynamics.

OBJECTIVE

The aim of the study was to investigate the relative effects of HBP-CRT and BVP-CRT on ventricular repolarization.

METHODS

Patients with LBBB referred for BVP-CRT underwent intra-procedural non-invasive epicardial mapping during atrial pacing (intrinsic LBBB), BVP-CRT, and temporary HBP. When HBP corrected LBBB, changes from baseline (LBBB) in overall and left ventricular (LV) repolarization dispersion (ΔVRT, ΔLVRT), repolarization gradient (ΔVRG, ΔLVRG) and activation-recovery interval (ARI) dispersion (ΔVARI, ΔLVARI) were measured.

RESULTS

17 patients had full datasets. BVP-CRT had no effect on global repolarization dispersion, gradient steepness or ARI (ΔVRT -1.5 ms, 95% confidence interval [CI] -15.4 to +12.4, P = .82; ΔVRG -0.00549 ms/mm, -0.106 to +0.0954, P = .9; ΔVARI -5.0 ms, -24.3 to +14.3, P = .59) and worsened the parameters in the LV (ΔLVRT +14.5 ms, +0.05 to +28.9, P = .049; ΔLVRG +0.0931 ms/mm, -0.0635 to +0.25, P = .226, ΔLVARI +28.6 ms, 95% CI +6.0 to +51.2, P = .02). HBP-CRT significantly improved global repolarization dispersion, gradient steepness and ARI (ΔLVRT +14.5 ms, +0.05 to +28.9, P = .049; ΔLVRG +0.0931 ms/mm, -0.0635 to +0.25, P = .226; ΔVARI -49.5 ms, -69.0 to -29.9, P < .0001) and within the LV (ΔLVRT -38.2 ms, -48.7 to -27.6, P < .001; ΔLVRG -0.228 ms/mm, -0.334 to -0.122, P = .0003; ΔLVARI -37.2 ms, -59.4 to -15.0, P = .003).

CONCLUSION

HBP-CRT improves LBBB-induced repolarization abnormalities through improved activation synchrony and ARI modulation. BVP-CRT does not improve, and appears to worsen, LV repolarization parameters.

Для цитирования: Samways Jack W, Cheng Timothy, Chow Ji-Jian, Shun-Shin Matthew J, Ali Nadine, Keene Daniel, Howard James P, Naraen Akriti, Saleh Keenan, Kaza Nandita, Sharma Chet, Mohal Jagdeep S, Reddy Rohin K, Strocchi Marina, Niederer Steven A, Peters Nicholas S, Linton Nicholas W F, Kanagaratnam Prapa, Ng Fu Siong, Francis Darrel P, Whinnett Zachary I, Arnold Ahran D. Ventricular repolarization is improved by His resynchronization therapy but not biventricular pacing.. Heart rhythm. 2025. DOI: 10.1016/j.hrthm.2025.09.037.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.