MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.gie.2024.04.013

Медицинская библиотека · Gastrointestinal endoscopy · 2024

Computer-aided diagnosis improves characterization of Barrett's neoplasia by general endoscopists (with video).

Jukema Jelmer B, Kusters Carolus H J, Jong Martijn R, Fockens Kiki N, Boers Tim, van der Putten Joost A, Pouw Roos E, Duits Lucas C, Weusten Bas L A M, Herrero Lorenza Alvarez, Houben Martin H M G, Nagengast Wouter B, Westerhof Jessie, Alkhalaf Alaa, Mallant-Hent Rosalie, Scholten Pieter, Ragunath Krish, Seewald Stefan, Elbe Peter, Silva Francisco Baldaque, Barret Maximilien, Ortiz Fernández-Sordo Jacobo, Moral Villarejo Guiomar, Pech Oliver, Beyna Torsten, Montazeri Nahid S M, der Sommen Fons van, de With Peter H, de Groof A Jeroen, Bergman Jacques J, BONS-AI consortium

СтатьяМногоцентровое исследованиеVideo-Audio MediaПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND AIMS: Characterization of visible abnormalities in patients with Barrett's esophagus (BE) can be challenging, especially for inexperienced endoscopists. This results in suboptimal diagnostic accuracy and poor interobserver agreement. Computer-aided diagnosis (CADx) systems may assist endoscopists. We aimed to develop, validate, and benchmark a CADx system for BE neoplasia.

METHODS

The CADx system received pretraining with ImageNet and then consecutive domain-specific pretraining with GastroNet, which includes 5 million endoscopic images. It was subsequently trained and internally validated using 1758 narrow-band imaging (NBI) images of early BE neoplasia (352 patients) and 1838 NBI images of nondysplastic BE (173 patients) from 8 international centers. CADx was tested prospectively on corresponding image and video test sets with 30 cases (20 patients) of BE neoplasia and 60 cases (31 patients) of nondysplastic BE. The test set was benchmarked by 44 general endoscopists in 2 phases (phase 1, no CADx assistance; phase 2, with CADx assistance). Ten international BE experts provided additional benchmark performance.

RESULTS

Stand-alone sensitivity and specificity of the CADx system were 100% and 98% for images and 93% and 96% for videos, respectively. CADx outperformed general endoscopists without CADx assistance in terms of sensitivity (P = .04). Sensitivity and specificity of general endoscopists increased from 84% to 96% and 90% to 98% with CAD assistance (P < .001). CADx assistance increased endoscopists' confidence in characterization (P < .001). CADx performance was similar to that of the BE experts.

CONCLUSIONS

CADx assistance significantly increased characterization performance of BE neoplasia by general endoscopists to the level of expert endoscopists. The use of this CADx system may thereby improve daily Barrett surveillance.

Для цитирования: Jukema Jelmer B, Kusters Carolus H J, Jong Martijn R, Fockens Kiki N, Boers Tim, van der Putten Joost A, Pouw Roos E, Duits Lucas C, Weusten Bas L A M, Herrero Lorenza Alvarez, Houben Martin H M G, Nagengast Wouter B, Westerhof Jessie, Alkhalaf Alaa, Mallant-Hent Rosalie, Scholten Pieter, Ragunath Krish, Seewald Stefan, Elbe Peter, Silva Francisco Baldaque, Barret Maximilien, Ortiz Fernández-Sordo Jacobo, Moral Villarejo Guiomar, Pech Oliver, Beyna Torsten, Montazeri Nahid S M, der Sommen Fons van, de With Peter H, de Groof A Jeroen, Bergman Jacques J, BONS-AI consortium. Computer-aided diagnosis improves characterization of Barrett's neoplasia by general endoscopists (with video).. Gastrointestinal endoscopy. 2024. DOI: 10.1016/j.gie.2024.04.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.