Smartphone-enabled magneto-immunofluorescence platform for rapid isomiroestrol detection in plants.

Phongsanam Nopphakon, Sae-Foo Worapol, Phetduang Samuch, Putalun Waraporn, Nijpanich Supinya, Tasarin Sawanya, Srimongkon Pitragorn, Ngamdee Kessarin, Ngeontae Wittaya

СтатьяПеревод в очереди

Аннотация

This study introduces a portable magneto-immunofluorescence platform for isomiroestrol (IME) detection in plant samples, overcoming limitations of traditional ELISA methods that require extensive washing, blocking steps, and laboratory equipment. The approach utilizes amino-functionalized magnetic nanoparticles for selective IME capture via formaldehyde-mediated Mannich reaction, coupled with a dual-antibody detection system (monoclonal antibodies and horseradish peroxidase-labeled polyclonal antibody (pAb-HRP)). The immunofluorescence detection principle was based on the enzymatic conversion of o-phenylenediamine (OPD) by HRP in the presence of hydrogen peroxide to produce the highly fluorescent 2,3-diaminophenazine (DAP). The fluorescence intensity is measured using a smartphone-based portable device, providing a cost-effective alternative to conventional spectrofluorometers. The method demonstrates excellent linearity (R2 = 0.9960) across 0.025-1.5 μg mL-1, with a 0.021 μg mL-1 detection limit. Requiring only two washing steps at ambient temperature, this platform significantly reduces analysis time while maintaining analytical performance comparable to standard ELISA techniques. This advancement enables accessible, rapid, and reliable field-based IME detection in plant samples.

Для цитирования: Phongsanam Nopphakon, Sae-Foo Worapol, Phetduang Samuch, Putalun Waraporn, Nijpanich Supinya, Tasarin Sawanya, Srimongkon Pitragorn, Ngamdee Kessarin, Ngeontae Wittaya. Smartphone-enabled magneto-immunofluorescence platform for rapid isomiroestrol detection in plants.. Talanta. 2025. DOI: 10.1016/j.talanta.2025.129262.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.