MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.echo.2018.08.009

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2018

The Incremental Benefit of Color Tissue Doppler in Fetal Arrhythmia Assessment.

Alvarez Silvia G V, Khoo Nee S, Colen Timothy, McBrien Angela, Eckersley Luke, Brooks Paul, Savard Winnie, Hornberger Lisa K

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Accurate fetal arrhythmia (FA) diagnosis is key for effective management. Currently, FA assessment relies on standard echocardiography-based techniques (M mode and spectral Doppler), which require adequate fetal position and cursor alignment to define temporal relationships of mechanical events. Few data exist on the application of color Doppler tissue imaging (c-DTI) in FA assessment. The aim of this study was to examine the feasibility and clinical applicability of c-DTI in FA assessment in comparison with standard techniques.

METHODS

Pregnancies with diagnosed FA were prospectively recruited to undergo c-DTI following fetal echocardiography. Multiple-cycle four-chamber clips in any orientation were recorded (mean frame rate, 180 ± 16 frames/sec). With offline analysis, sample volumes were placed on atrial (A) and ventricular (V) free walls for simultaneous recordings. Atrial and ventricular rates, intervals (for atrial-ventricular conduction and tachyarrhythmia mechanism), and relationships were assessed to decipher FA mechanism. FA diagnosis by c-DTI, conventional echocardiographic techniques, and postnatal electrocardiography and/or Holter monitoring were compared.

RESULTS

FA was assessed by c-DTI in 45 pregnancies at 15 to 39 weeks, including 16 with atrial and/or ventricular ectopic beats; 18 with supraventricular tachyarrhythmias, including ectopic atrial tachycardia in 11, atrioventricular reentrant tachycardia in four, atrial flutter in two, and intermittent atrial flutter and junctional ectopic rhythm in one; three with ventricular tachycardias; and eight with bradycardias or atrioventricular conduction pathology, including five with complete atrioventricular block (AVB), one with first-degree AVB evolving into complete AVB, one with second-degree AVB, and one with sinus bradycardia. After training, FA diagnosis by c-DTI could be made irrespective of fetal orientation within 10 to 15 min. FA diagnosis by c-DTI concurred with standard techniques in 41 cases (91%), with additional findings identified by c-DTI in 10. c-DTI led to new FA diagnoses in four cases (9%) not definable by standard techniques. FA diagnosis by c-DTI was confirmed in all 20 with persistent arrhythmias after birth, including three with new diagnoses defined by c-DTI. c-DTI was particularly helpful in deciphering SVT mechanism (long vs short ventricular-atrial interval) in all 18 cases, whereas standard techniques permitted definition in only half.

CONCLUSIONS

c-DTI with offline analysis permits rapid and accurate definition of FA mechanism, providing new information in nearly one-third of affected pregnancies.

Для цитирования: Alvarez Silvia G V, Khoo Nee S, Colen Timothy, McBrien Angela, Eckersley Luke, Brooks Paul, Savard Winnie, Hornberger Lisa K. The Incremental Benefit of Color Tissue Doppler in Fetal Arrhythmia Assessment.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 2018. DOI: 10.1016/j.echo.2018.08.009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.