MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-026-59622-4

Медицинская библиотека · Scientific reports · 2026

Computational investigation on dynamic response of supercritical natural circulation loop under rolling motion condition.

Srivastava Tanuj, Tilak Abhilash K, Kumar Nitesh, Gond Ashok Kumar, Basu Dipankar N

СтатьяПеревод в очереди

Аннотация

This study examines the performance of a supercritical natural circulation loop (sNCL) under rolling motion using a one-dimensional transient numerical model. Heating powers of 1000, 1250 and 1500 W are analyzed with rolling amplitudes of 5% and 15% relative to gravitational acceleration (g), and periods ranging from 4 s to 75 s. At 1000 W, the system maintains dynamic steady-state. However, at 1500 W, when the rolling frequency (0.196 Hz) matches the system's natural frequency, large oscillations and flow reversal occur. Heater outlet temperatures fluctuate near the pseudocritical point (307.8 K), affecting buoyancy and friction forces. For the operating conditions investigated in the present study, the buoyancy parameter was observed to vary approximately between 2570 and 3100. A 4 s rolling period at 15% amplitude leads to flow reversal within 20 s, whereas longer periods (75 s) stabilize the loop. The findings highlight the importance of accounting for rolling-induced instabilities in marine sNCL applications, providing preliminary physical insights relevant to sNCL operation under dynamic gravity environments.

Для цитирования: Srivastava Tanuj, Tilak Abhilash K, Kumar Nitesh, Gond Ashok Kumar, Basu Dipankar N. Computational investigation on dynamic response of supercritical natural circulation loop under rolling motion condition.. Scientific reports. 2026. DOI: 10.1038/s41598-026-59622-4.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.