DOI 10.1186/s13054-024-05168-8

Медицинская библиотека · Critical care (London, England) · 2024

Feasibility and safety of ultra-low volume ventilation (≤ 3 ml/kg) combined with extra corporeal carbon dioxide removal (ECCO2R) in acute respiratory failure patients.

Monet Clément, Renault Thomas, Aarab Yassir, Pensier Joris, Prades Albert, Lakbar Ines, Le Bihan Clément, Capdevila Mathieu, De Jong Audrey, Molinari Nicolas, Jaber Samir

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Ultra-protective ventilation is the combination of low airway pressures and tidal volume (Vt) combined with extra corporeal carbon dioxide removal (ECCO2R). A recent large study showed no benefit of ultra-protective ventilation compared to standard ventilation in ARDS (Acute Respiratory Distress Syndrome) patients. However, the reduction in Vt failed to achieve the objective of less than or equal to 3 ml/kg predicted body weight (PBW). The main objective of our study was to assess the feasibility of the ultra-low volume ventilation (Vt ≤ 3 ml/kg PBW) facilitated by ECCO2R in acute respiratory failure patients.

METHODS

Retrospective analysis of a prospective cohort of patients with either high or low blood flow veno-venous ECCO2R devices. A session was defined as a treatment of ECCO2R from the start to the removal of the device (one patient could have one more than one session). Primary endpoint was the proportion of sessions during which a Vt less or equal to 3 ml/kg PBW at 24 h after the start of ECCO2R was successfully achieved for at least 12 h. Secondary endpoints were respiratory variables, rate of adverse events and outcomes.

RESULTS

Forty-five ECCO2R sessions were recorded among 41 patients. Ultra-low volume ventilation (tidal volume ≤ 3 ml/kg PBW, success group) was successfully achieved at 24 h in 40.0% sessions (18 out of 45 sessions, confidence interval 25.3-54.6%). At 24 h, tidal volume in the failure group was 4.1 [3.8-4.5] ml/kg PBW compared to 2.1 [1.9-2.5] in the success group (p < 0.001). After multivariate analysis, blood flow rate was significantly associated with success of ultra-low volume ventilation (adjusted OR per 100 ml/min increase 1.51 (95%CI 1.21-1.90, p = 0.0003).

CONCLUSION

Ultra-low volume ventilation (≤ 3 ml/kg PBW) was feasible in 18 out of 45 sessions. Higher blood flow rates were associated with the success of ultra-low volume ventilation.

Для цитирования: Monet Clément, Renault Thomas, Aarab Yassir, Pensier Joris, Prades Albert, Lakbar Ines, Le Bihan Clément, Capdevila Mathieu, De Jong Audrey, Molinari Nicolas, Jaber Samir. Feasibility and safety of ultra-low volume ventilation (≤ 3 ml/kg) combined with extra corporeal carbon dioxide removal (ECCO2R) in acute respiratory failure patients.. Critical care (London, England). 2024. DOI: 10.1186/s13054-024-05168-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.