MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcmg.2018.11.033

Медицинская библиотека · JACC. Cardiovascular imaging · 2019

Diagnostic Value of Advanced Imaging Modalities for the Detection and Differentiation of Prosthetic Valve Obstruction: A Systematic Review and Meta-Analysis.

Kim Jin Young, Suh Young Joo, Han Kyunghwa, Kim Young Jin, Choi Byoung Wook

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

OBJECTIVES

This meta-analysis investigated the diagnostic values of transthoracic echocardiography (TTE), 2-dimensional (2D) and 3-dimensional (3D) transesophageal echocardiography (TEE), and multidetector-row computed tomography (MDCT) in patients with suspected mechanical prosthetic valve obstruction (PVO) for detecting subprosthetic mass and differentiating its causes.

BACKGROUND

Diagnostic values of advanced imaging modalities, such as MDCT and TEE, for the detection and differentiation of PVO have not been investigated.

METHODS

PubMed and EMBASE were systematically searched for studies that evaluated PVO using imaging modalities. The modified Quality Assessment of Diagnostic Accuracy Studies-2 tool was used to evaluate study quality. Pooled sensitivity of each modality for PVO detection and pooled diagnostic accuracy of TEE and MDCT for differentiating the causes of PVO were analyzed. Study heterogeneity was also assessed.

RESULTS

Seventeen studies (229 patients) that used at least 1 index tool among TTE, TEE, or MDCT were included. For detecting a subprosthetic mass that caused PVO, 3D TEE and MDCT showed a higher sensitivity of 81% (95% confidence interval [CI]: 40% to 95%) and 88% (95% CI: 81% to 93%), respectively, compared with TTE (20%; 95% CI: 7% to 47%) and 2D TEE (68%; 95% CI: 46% to 84%). Pooled sensitivity and specificity for diagnosing thrombus as a cause of PVO was 75% (95% CI: 54% to 88%) and 75% (95% CI: 40% to 93%), respectively, for TEE and 45% (95% CI: 16% to 77%) and 90% (95% CI: 77% to 96%), respectively, for MDCT. Pooled sensitivity for diagnosing pannus as a cause of PVO was 62% (95% CI: 46% to 76%) for TEE and 85% (95% CI: 70% to 93%) for MDCT.

CONCLUSIONS

This meta-analysis suggested that MDCT and 3D TEE have higher sensitivity than do TTE and 2D TEE, and can be reliable imaging modalities for detecting a subprosthetic mass that causes PVO. Moreover, MDCT can more accurately differentiate the cause of PVO than does TEE.

Для цитирования: Kim Jin Young, Suh Young Joo, Han Kyunghwa, Kim Young Jin, Choi Byoung Wook. Diagnostic Value of Advanced Imaging Modalities for the Detection and Differentiation of Prosthetic Valve Obstruction: A Systematic Review and Meta-Analysis.. JACC. Cardiovascular imaging. 2019. DOI: 10.1016/j.jcmg.2018.11.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.