One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography.

Yamasaki Yuzo, Nagao Michinobu, Kawanami Satoshi, Kamitani Takeshi, Sagiyama Koji, Yamanouchi Torahiko, Sakamoto Ichiro, Yamamura Kenichiro, Yabuuchi Hidetake, Honda Hiroshi

СтатьяПеревод в очереди

Аннотация

OBJECTIVES

To investigate the feasibility and accuracy of measurement of the pulmonary to systemic blood flow ratio (Qp/Qs) and defect and rim sizes in secundum atrial septal defects (ASDs) using 256-slice CT, compared to the reference transoesophageal echocardiography (TEE) and right heart catheterization (RHC) measurements.

METHODS

Twenty-three consecutive adult patients with secundum ASDs who underwent retrospective ECG-gated coronary CT angiography (CCTA), TEE and RHC were enrolled in this study. Right ventricular (RV) and left ventricular (LV) stroke volumes (SV) were calculated by biventricular volumetry of CCTA. Qp/Qs-CT was defined as RVSV/LVSV. The sizes of the defect and rim were measured by multi-planar reconstruction CT images. Correlations between Qp/Qs-CT and Qp/Qs-RHC and between the defect diameter obtained by CT and TEE were analyzed by Pearson's coefficient analysis. Rim sizes by CT and TEE were compared by paired t-test.

RESULTS

Qp/Qs-CT was significantly correlated with Qp/Qs-RHC (r = 0.83, p < 0.0001), and the defect diameter by CT was significantly correlated with that by TEE (r = 0.95, p < 0.0001). There was no significant difference between CT and TEE in measurements of rim size.

CONCLUSIONS

256-slice CCTA allows measuring Qp/Qs and size of defects and rims in patients with secundum ASDs, accomplishing pretreatment evaluation non-invasively and comprehensively.

KEY POINTS: • Quantification of left-to-right shunting can be performed reliably and accurately by CT. • The sizes of defects and rims can be measured accurately using 256-slice CT. • 256-slice CT permits pretreatment evaluation of ASD non-invasively and comprehensively.

Для цитирования: Yamasaki Yuzo, Nagao Michinobu, Kawanami Satoshi, Kamitani Takeshi, Sagiyama Koji, Yamanouchi Torahiko, Sakamoto Ichiro, Yamamura Kenichiro, Yabuuchi Hidetake, Honda Hiroshi. One-stop shop assessment for atrial septal defect closure using 256-slice coronary CT angiography.. European radiology. 2016. DOI: 10.1007/s00330-016-4407-2.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.