MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s10661-005-7058-3

Медицинская библиотека · Environmental monitoring and assessment · 2005

Enumeration of Legionella pneumophila in cooling tower water systems.

Türetgen Irfan, Sungur Esra Ilhan, Cotuk Aysin

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Legionella pneumophila, the causative agent of Legionnaires' disease, is known to colonise and frequently grow in cooling tower waters. Disease is acquired by inhaling aerosol contaminated by legionellae. Determination of the count of Legionella pneumophila in cooling tower waters may, therefore, be useful for risk assessment. In our survey, 103 water samples from 50 cooling towers were examined over a five-year period to indicate the seasonal distribution and the ecology of L. pneumophila, as regards temperature and pH. L. pneumophila serogroup 1 was found in 44% of the isolated strains, which is primarily responsible for the majority of Legionnaires' disease. The large majority of examined towers had levels of L. pneumophila in the high-risk category. These cooling towers have been linked to many outbreaks of Legionnaires' disease.

Для цитирования: Türetgen Irfan, Sungur Esra Ilhan, Cotuk Aysin. Enumeration of Legionella pneumophila in cooling tower water systems.. Environmental monitoring and assessment. 2005. DOI: 10.1007/s10661-005-7058-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.