DOI 10.1128/jcm.42.12.5913-5916.2004
Comparison of five methods for extraction of Legionella pneumophila from respiratory specimens.
Аннотация
The efficiencies of five commercially available nucleic acid extraction methods were evaluated for the recovery of a standardized inoculum of Legionella pneumophila in respiratory specimens (sputum and bronchoalveolar lavage [BAL] specimens). The concentrations of Legionella DNA recovered from sputa with the automated MagNA Pure (526,200 CFU/ml) and NucliSens (171,800 CFU/ml) extractors were greater than those recovered with the manual methods (i.e., Roche High Pure kit [133,900 CFU/ml], QIAamp DNA Mini kit [46,380 CFU/ml], and ViralXpress kit [13,635 CFU/ml]). The rank order was the same for extracts from BAL specimens, except that for this specimen type the QIAamp DNA Mini kit recovered more than the Roche High Pure kit.