MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7863/jum.2002.21.2.113

Медицинская библиотека · Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine · 2002

Role of uterine artery Doppler flow in fibroid embolization.

McLucas Bruce, Perrella Rita, Goodwin Scott, Adler Louis, Dalrymple Jerry

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine whether Doppler flow measurements are useful in predicting variables associated with uterine fibroid embolization, including shrinkage of the uterus and myomas, adenomyosis, and uterine fibroid embolization failure.

METHODS

A group of 227 patients with menorrhagia or postmenopausal bleeding secondary to uterine myomas were evaluated with uterine artery Doppler flow sonography before uterine fibroid embolization. Doppler flow measurements were repeated 6 months after uterine fibroid embolization for 188 of the patients. Data were analyzed for correlations between peak systolic velocity and uterine fibroid embolization patient data, including size and shrinkage of the uterus and myomas, embolization particle size, adenomyosis, and uterine fibroid embolization failure.

RESULTS

Initial peak systolic velocity was positively correlated with the size and shrinkage of myomas and uterine volume. Peak systolic velocity was positively correlated with the size and load of embolization particles and was significantly lower (mean, 33.2 cm/s) in patients with adenomyosis than those without adenomyosis (mean, 39.3 cm/s). High peak systolic velocity (>64 cm/s) was a significant predictor of failure. Postembolization peak systolic velocity (mean, 21.85 cm/s) was significantly lower than preembolization peak systolic velocity (mean, 40.33 cm/s) and was not correlated with uterine fibroid embolization variables.

CONCLUSIONS

Doppler flow measurements can aid in predicting adenomyosis and uterine fibroid embolization failure. Postembolization peak systolic velocity did not show value.

Для цитирования: McLucas Bruce, Perrella Rita, Goodwin Scott, Adler Louis, Dalrymple Jerry. Role of uterine artery Doppler flow in fibroid embolization.. Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine. 2002. DOI: 10.7863/jum.2002.21.2.113.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.