Journal of chromatography. B, Analytical technologies in the biomedical and life sciences · 2024
Development and validation of an LC-MS/MS method for quantifying diamorphine and its major metabolites 6-monoacetylmorphine, morphine, morphine-3-glucuronide, and morphine-6-glucuronide in human plasma.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Thomann Jan, Vogt Severin B, Guessoum Adrian, Meyer Maximilian, Vogel Marc, Liechti Matthias E, Luethi Dino, Duthaler Urs
Аннотация
Diamorphine, commonly known as heroin, is a semi-synthetic opioid analgesic. In the context of heroin-assisted treatment for opioid-dependent patients, diamorphine is mostly administered intravenously. However, recent attention has shifted towards intranasal administration as a better-tolerated alternative to the intravenous route. Here, we developed and validated a rapid bioanalytical method for the simultaneous quantification of diamorphine and its major metabolites 6-monoacetylmorphine, morphine, morphine-3-glucuronide, and morphine-6-glucuronide in human plasma using liquid chromatography-tandem mass spectrometry (LC-MS/MS). A straightforward protein precipitation extraction step was used for sample preparation. Chromatographic analyte separation was achieved using a Kinetex EVO C18 analytical column and a mobile phase gradient comprising an aqueous solution of ammonium hydrogen carbonate and methanol supplied with formic acid. Employing positive electrospray ionization and scheduled multiple reaction monitoring, we established a quantification range of 1-1,000 ng/mL for all analytes. Our validation results demonstrate a mean intra-assay accuracy of 91-106% and an intra-assay precision (CV) between 2 and 9% for all analytes and over three validation runs. The method exhibits a high extraction recovery (> 87%) and a negligible matrix effect (99-125%). Furthermore, no interferences with endogenous plasma compounds were detected. Lastly, we applied the method to assess the plasma concentrations of an opioid-dependent patient after the intranasal administration of diamorphine in a clinical study. In summary, we have successfully developed a rapid, highly reliable, and straightforward bioanalytical method for quantifying diamorphine and its metabolites in low amounts of clinical plasma samples.