BACKGROUND

Study was performed in order: (i) to assess the comparability of glucose, bilirubin, hemoglobin, leukocyte esterase, and protein; (ii) to assess accuracy of glucose, bilirubin, hemoglobin, leukocyte esterase, and protein; and (iii) to evaluate interference of ascorbic acid on the glucose, bilirubin, hemoglobin, and nitrite determination using 2 different dipsticks: iChem Velocity, Iris Diagnostics and Combur-10M, Roche Diagnostics.

METHODS

Random urine specimens were included in the study. Comparability, accuracy, and ascorbic acid interference testing were performed.

RESULTS

Obtained results have shown almost perfect agreement for all parameters between 2 dipsticks in samples with negative ascorbic acid. Agreement in samples with positive ascorbic acid was not acceptable for bilirubin, protein, nitrite, and hemoglobin. Accuracy was not acceptable for hemoglobin and leukocyte esterase on both dipsticks. Ascorbic acid interference examination has shown that intensity of interference differs between dipsticks. Ascorbic acid interferes with glucose, hemoglobin, nitrite, and bilirubin at different concentrations causing false-negative results.

CONCLUSION

Obtained results indicate that it is necessary to determine diagnostic accuracy of used dipstick in order to define purpose of urinalysis. It is very important to choose dipstick with ascorbic acid indicator and to examine ascorbic acid impact on dipstick analytes independently of manufacturer claims.

Для цитирования: Unic Adriana, Nikolac Gabaj Nora, Miler Marijana, Culej Jelena, Lisac Adrijana, Horvat Anita, Vrkic Nada. Ascorbic acid-A black hole of urine chemistry screening.. Journal of clinical laboratory analysis. 2018. DOI: 10.1002/jcla.22390.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.