OBJECTIVE

To establish an accurate, convenient and sensitive quantitative fluorescence method for the determination of diphacinone (DPN) in urine.

METHODS

Diphacinone was complexed with europium ion (Eu3+) at the presence of DL-histidine, polyvinylpyrrolidone (PVP) and ammonia-ammonium chloride (NH3 -NH4 Cl) buffer solution to form a multiple complex of DPN-Eu(3+) -DL-histidine-NH3-PVP fluorescence system, and the fluorescence sensitivity was greatly enhanced by the rare earth element of yttrium ion (Y3+ ). The excitation and emission wavelengths were 330 nm and 612 nm, respectively.

RESULTS

The optimum conditions were Eu3+ 10.0 mg/L,Y3+ 20.0 mg/L, DL-histidine 0.01%, PVP 0.05% at pH 9.0. Under the optimum conditions, fluorescence intensity of the system was a linear function of the concentration of diphacinone in the range of 0.2 - 10.0 mg/L, the limit of quantification was 0.2 mg/L. The spiked recoveries for DPN in urine were 87.0% - 97.3%, the intra-and inter-day RSDs were between 3.4% - 4.7% and 4.8% - 6.6%, respectively.

CONCLUSION

The established method is simple, accurate and reliable, and it is satisfactory for the determination of DPN in urine and can be used for DPN poisoned patients for the rapid clinical diagnosis.

Для цитирования: Chen Xiaohong, Cai Meiqiang, Jin Micong. [Study on the enhancement diphacinone-europium fluorescence system and application for determination of the residue in urine].. Wei sheng yan jiu = Journal of hygiene research. 2011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.