European radiology · 2022
Depiction of breast cancers on digital mammograms by artificial intelligence-based computer-assisted diagnosis according to cancer characteristics.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lee Si Eun, Han Kyunghwa, Yoon Jung Hyun, Youk Ji Hyun, Kim Eun-Kyung
Аннотация
OBJECTIVE: To evaluate how breast cancers are depicted by artificial intelligence-based computer-assisted diagnosis (AI-CAD) according to clinical, radiological, and pathological factors.
MATERIALS AND METHODS: From January 2017 to December 2017, 896 patients diagnosed with 930 breast cancers were enrolled in this retrospective study. Commercial AI-CAD was applied to digital mammograms and abnormality scores were obtained. We evaluated the abnormality score according to clinical, radiological, and pathological characteristics. False-negative results were defined by abnormality scores less than 10.
RESULTS: The median abnormality score of 930 breasts was 87.4 (range 0-99). The false-negative rate of AI-CAD was 19.4% (180/930). Cancers with an abnormality score of more than 90 showed a high proportion of palpable lesions, BI-RADS 4c and 5 lesions, cancers presenting as mass with or without microcalcifications and invasive cancers compared with low-scored cancers (all p < 0.001). False-negative cancers were more likely to develop in asymptomatic patients and extremely dense breasts and to be diagnosed as occult breast cancers and DCIS compared to detected cancers.
CONCLUSION: Breast cancers depicted with high abnormality scores by AI-CAD are associated with higher BI-RADS category, invasive pathology, and higher cancer stage.
KEY POINTS: • High-scored cancers by AI-CAD included a high proportion of BI-RADS 4c and 5 lesions, masses with or without microcalcifications, and cancers with invasive pathology. • Among invasive cancers, cancers with higher T and N stage and HER2-enriched subtype were depicted with higher abnormality scores by AI-CAD. • Cancers missed by AI-CAD tended to be in asymptomatic patients and extremely dense breasts and to be diagnosed as occult breast cancers by radiologists.
MATERIALS AND METHODS: From January 2017 to December 2017, 896 patients diagnosed with 930 breast cancers were enrolled in this retrospective study. Commercial AI-CAD was applied to digital mammograms and abnormality scores were obtained. We evaluated the abnormality score according to clinical, radiological, and pathological characteristics. False-negative results were defined by abnormality scores less than 10.
RESULTS: The median abnormality score of 930 breasts was 87.4 (range 0-99). The false-negative rate of AI-CAD was 19.4% (180/930). Cancers with an abnormality score of more than 90 showed a high proportion of palpable lesions, BI-RADS 4c and 5 lesions, cancers presenting as mass with or without microcalcifications and invasive cancers compared with low-scored cancers (all p < 0.001). False-negative cancers were more likely to develop in asymptomatic patients and extremely dense breasts and to be diagnosed as occult breast cancers and DCIS compared to detected cancers.
CONCLUSION: Breast cancers depicted with high abnormality scores by AI-CAD are associated with higher BI-RADS category, invasive pathology, and higher cancer stage.
KEY POINTS: • High-scored cancers by AI-CAD included a high proportion of BI-RADS 4c and 5 lesions, masses with or without microcalcifications, and cancers with invasive pathology. • Among invasive cancers, cancers with higher T and N stage and HER2-enriched subtype were depicted with higher abnormality scores by AI-CAD. • Cancers missed by AI-CAD tended to be in asymptomatic patients and extremely dense breasts and to be diagnosed as occult breast cancers by radiologists.