MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/epi4.12827

Медицинская библиотека · Epilepsia open · 2023

Scalp high-frequency oscillations differentiate neonates with seizures from healthy neonates.

Cserpan Dorottya, Guidi Greta, Alessandri Beatrice, Fedele Tommaso, Rüegger Andrea, Pisani Francesco, Sarnthein Johannes, Ramantani Georgia

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

We aimed to investigate (1) whether an automated detector can capture scalp high-frequency oscillations (HFO) in neonates and (2) whether scalp HFO rates can differentiate neonates with seizures from healthy neonates.

METHODS

We considered 20 neonates with EEG-confirmed seizures and four healthy neonates. We applied a previously validated automated HFO detector to determine scalp HFO rates in quiet sleep.

RESULTS

Etiology in neonates with seizures included hypoxic-ischemic encephalopathy in 11 cases, structural vascular lesions in 6, and genetic causes in 3. The HFO rates were significantly higher in neonates with seizures (0.098 ± 0.091 HFO/min) than in healthy neonates (0.038 ± 0.025 HFO/min; P = 0.02) with a Hedge's g value of 0.68 indicating a medium effect size. The HFO rate of 0.1 HFO/min/ch yielded the highest Youden index in discriminating neonates with seizures from healthy neonates. In neonates with seizures, etiology, status epilepticus, EEG background activity, and seizure patterns did not significantly impact HFO rates.

SIGNIFICANCE: Neonatal scalp HFO can be detected automatically and differentiate neonates with seizures from healthy neonates. Our observations have significant implications for neuromonitoring in neonates. This is the first step in establishing neonatal HFO as a biomarker for neonatal seizures.

Для цитирования: Cserpan Dorottya, Guidi Greta, Alessandri Beatrice, Fedele Tommaso, Rüegger Andrea, Pisani Francesco, Sarnthein Johannes, Ramantani Georgia. Scalp high-frequency oscillations differentiate neonates with seizures from healthy neonates.. Epilepsia open. 2023. DOI: 10.1002/epi4.12827.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.