MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1074/jbc.m108856200

Медицинская библиотека · The Journal of biological chemistry · 2001

Promoter clearance by T7 RNA polymerase. Initial bubble collapse and transcript dissociation monitored by base analog fluorescence.

Liu Cuihua, Martin Craig T

СтатьяПоддержка службы здравоохранения СШАПеревод в очереди

Аннотация

Footprinting, fluorescence, and x-ray structural information from the initial, promoter-bound complex of T7 RNA polymerase describes the very beginning of the initiation of transcription, whereas recent fluorescence and biochemical studies paint a preliminary picture of an elongation complex. The current work focuses on the transition from an initially transcribing, promoter-bound complex to an elongation complex clear of the promoter. Fluorescence quenching is used to follow the melted state of the DNA bubble, and a novel approach using a locally mismatched fluorescent base analog reports on the local structure of the heteroduplex. Fluorescent base analogs placed at positions -2 and -1 of the promoter indicate that this initially melted, nontranscribed region remains melted as the polymerase translocates through to position +8. In progressing to position +9, this region of the DNA bubble begins to collapse. Probes placed at positions +1 and +2 of the template strand indicate that the 5' end of the RNA remains in a heteroduplex as the complex translocates to position +10. Subsequent translocation leads to sequential dissociation of the first 2 bases of the RNA. These results show that the initially transcribing complex bubble can reach a size of up to 13 base pairs and a maximal heteroduplex length of 10 base pairs. They further indicate that initial bubble collapse precedes dissociation of the 5' end of the RNA.

Для цитирования: Liu Cuihua, Martin Craig T. Promoter clearance by T7 RNA polymerase. Initial bubble collapse and transcript dissociation monitored by base analog fluorescence.. The Journal of biological chemistry. 2001. DOI: 10.1074/jbc.m108856200.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.