MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/j.1476-5381.2010.00934.x

Медицинская библиотека · British journal of pharmacology · 2010

The Electro-Mechanical window: a risk marker for Torsade de Pointes in a canine model of drug induced arrhythmias.

van der Linde H J, Van Deuren B, Somers Y, Loenders B, Towart R, Gallacher D J

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND AND PURPOSE: In cardiovascular pharmacology, electrical and mechanical events can be distinguished, and the phrase 'electro-mechanical window' (EMw) describes the temporal difference between these events. We studied whether changes in EMw have potential predictive value for the occurrence of arrhythmias in fentanyl/etomidate-anaesthetized beagle (FEAB) dogs.

EXPERIMENTAL APPROACH: The EMw was calculated as differences between the QT interval and QLVP(end) in FEAB dogs during atrial pacing, treatment with isoprenaline or atropine, body temperature changes and induction of Torsade de Pointes (TdP) in an LQT1 model.

KEY

RESULTS

The electrical systole (QT interval) was shorter than the duration of the mechanical event (QLVP(end) ), providing a positive EMw. Atrial pacing, atropine or body temperature changes had no major effects on EMw, despite large changes in QT duration. However, β-adrenoceptor stimulation (with isoprenaline) decreased the EMw (from 90 to 5 ms) and in combination with HMR1556, a blocker of the slowly activating potassium current (I(Ks) ), induced a large negative EMw (-109ms) and TdP. Prevention of TdP by atenolol or verapamil was associated with a less negative EMw (-23 to -16ms). Mexiletine, a poorly effective long QT treatment, did not affect the EMw or prevent TdP induction.

CONCLUSIONS AND IMPLICATIONS: The EMw is a marker, other than QT prolongation, of TdP risk in the FEAB model. Therefore, we suggest examining the EMw as a risk marker in cardiovascular safety studies and as a potential biomarker to improve clinical management of long QT syndrome patients, especially in patients with borderline QT prolongation.

Для цитирования: van der Linde H J, Van Deuren B, Somers Y, Loenders B, Towart R, Gallacher D J. The Electro-Mechanical window: a risk marker for Torsade de Pointes in a canine model of drug induced arrhythmias.. British journal of pharmacology. 2010. DOI: 10.1111/j.1476-5381.2010.00934.x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.